Lenovo ThinkSystem ST550 LFF Silver 4114

  • (1) Intel Xeon Silver 4114 10C 85W 2.2GHz
  • ThinkSystem 8GB TruDDR4 2666 MHz (1Rx8 1.2V) RDIMM
  • Hard Drive : None (3.5")
  • ThinkSystem RAID 530-8i PCIe 12Gb Adapter (RAID 0, 1, 10, 5, and 50)
  • 2x 1GbE ports std; optional 1GbE, 10GBASE-T, and 10Gb SFP+;
    1x dedicated 1GbE management port
  • PCI Expansion slots: Up to 7 PCIe slots: 6 general purpose PCIe 3.0 slots
  • 4x 3.5-inch SAS/SATA hot-swap (4/8)
  • Power Supply 550W (230V/115V) Platinum Hot-Swap (1/2)
  • Form Factor/Height: 4U rackable tower
  • Warranty: 3 Year 24x7 Onsite
Manufacturer: Lenovo
$2,234.70

Chia sẻ sản phẩm:

Abstract

The Lenovo ThinkSystem ST550 2-socket 4U rack-mountable tower server provides outstanding performance and industry-leading reliability. It is ideal for small-to-medium businesses, distributed enterprises, retail, educational institutions and branch offices.

This product guide provides essential presales information to understand the ThinkSystem ST550 server, its key features and specifications, components and options, and configuration guidelines. This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the ST550 and consider its use in IT solutions.

Change History

Changes in the December 6 update:

  • Add a note to the Processor options section indicating that the option part numbers for processors include a system fan

 

Introduction

The Lenovo ThinkSystem ST550 2-socket 4U rack-mountable tower server provides outstanding performance and industry-leading reliability. It is ideal for small-to-medium businesses, distributed enterprises, retail, educational institutions, and remote/branch offices. The server supports two Intel Xeon Processor Scalable Family processors and up to 768 GB of TruDDR4 system memory.

Suggested uses: business workloads such as e-mail, workgroup applications, file & print, system management, web serving, and point-of-sale applications

Figure 1 shows the Lenovo ThinkSystem ST550.

Lenovo ThinkSystem ST550
Figure 1. Lenovo ThinkSystem ST550

Did you know?

The ThinkSystem ST550 is an enterprise-grade server with support for hot-swap power supplies, fans, and drives. It also offers full support of Lenovo XClarity Administrator for comprehensive systems management and includes the next generation UEFI-based Lenovo XClarity Provisioning Manager for system setup and diagnosis, and the Lenovo XClarity Controller management processor for ongoing systems management and alerting. These tools make the ST550 easy to deploy, integrate, service, and manage.

Key features

The ThinkSystem ST550 is a high-performance dual-socket tower server based on the new Intel Xeon Processor Scalable Family, supporting a wide range of processors to suit a wide range of budgets and application requirements.

Scalability and performance

The ST550  offers the following features to boost performance, improve scalability, and reduce costs:

  • Improves productivity by offering superior system performance with up to two processors, each with up to 20 cores, and core speeds up to 3.6 GHz.
  • Hyper-Threading Technology to maximize the concurrent execution of multithreaded applications, available with most processors.
  • Intelligent and adaptive system performance with energy-efficient Intel Turbo Boost Technology, available with most processors, allows CPU cores to run at maximum speeds during peak workloads by temporarily going beyond processor thermal design power (TDP).
  • Intel Virtualization Technology integrates hardware-level virtualization hooks that allow operating system vendors to better use the hardware for virtualization workloads.
  • Intel Advanced Vector Extensions 512 (AVX-512) enable acceleration of enterprise-class workloads, including databases and enterprise resource planning (ERP).
  • Each processor has six memory channels with memory speeds of up to 2666 MHz to help maximize system performance.
  • Up to 768 GB of memory capacity with 64 GB load-reduced DIMMs (LRDIMMs)
  • The 12 Gbps SAS internal storage connectivity doubles the data transfer rate compared to 6 Gb SAS solutions to maximize performance of storage I/O-intensive applications.
  • Flexible storage configurations support either 2.5-inch or 3.5-inch hot-swap drive bays or a combination of the two (hybrid configuration). Configurations with 3-5-inch simple-swap drive bays are also available. 
    • Up to 16x 2.5-inch drive bays with two 5.25-inch media drive bays available
    • Up to 20x 2.5-inch drive bays with the media bays converted to 4x 2.5-inch drive bays
    • Up to 8x 3.5-inch drive bays with two 5.25-inch media drive bays available
    • Up to 8x 3.5-inch + 4x 2.5-inch drive bays with the media bay conversion
    • Up to 8x 3.5-inch simple-swap drive bays
  • 3.5-inch drive bays support SAS and SATA HDDs and SSDs. 2.5-inch drive bays support SAS and SATA HDDs and SSDs, as well as NVMe drives.
  • Support for up to four NVMe PCIe SSDs in a 2.5-inch form factor maximizes drive I/O performance, in terms of throughput, bandwidth, and latency.
  • Scalable internal storage configurations provide for up to 95.4 TB of storage capacity using 8x 10TB 3.5-inch HDDs and 4x 3.84TB 2.5-inch SSDs.
  • The use of solid-state drives (SSDs) instead of, or along with, traditional hard disk drives (HDDs) can significantly improve I/O performance. An SSD can support up to 100 times more I/O operations per second (IOPS) than a typical HDD.
  • New high-speed RAID controllers from Broadcom provide 12 Gb SAS connectivity to the drive backplanes. A variety of RAID adapters are available, with cache up to 4 GB and support for 20 drives on a single controller.
  • Supports a new Lenovo patented-design M.2 adapter for convenient operating system boot functions. Available M.2 adapters support either one M.2 drive or two M.2 drives in a RAID 1 configuration for greater boot drive performance and reliability.
  • The server has two integrated Gigabit Ethernet ports.
  • The server offers PCI Express 3.0 I/O expansion capabilities that improve the theoretical maximum bandwidth by almost 100% (8 GT/ps per link using 128b/130b encoding) compared to the previous generation of PCI Express 2.0 (5 GT/s per link using 8b/10b encoding).
  • The server offers up to six PCIe 3.0 I/O expansion slots plus one slot reserved for the M.2 adapter
  • Support for up to two NVIDIA graphics processing units (GPUs) to maximize computing power.

Availability and serviceability

The ST550 provides the following features to simplify serviceability and increase system uptime:

  • The server offers Single Device Data Correction (SDDC, also known as Chipkill), Adaptive Double- Device Data Correction (ADDDC, also known as Redundant Bit Steering or RBS), memory mirroring, and memory rank sparing for redundancy in the event of a non-correctable memory failure.
  • The server offers hot-swap (HS) SSDs and HDDs, and supports RAID redundancy for data protection and greater system uptime.
  • Much like HS drives, simple-swap drives are mounted on an easy-to-remove tray and work with the same RAID options. Simple-swap require a system power-down before adding or replacing, however simple-swap drives are less expensive than hot-swap drives.
  • The Dual M.2 Boot Adapter supports RAID-1 which enables two installed M.2 drives to be configured as a redundant pair.
  • The server supports hot-swap power supplies; with two installed, they form a redundant pair to provide availability for business-critical applications. The server also offers an optional 4th fan which offers redundancy in most server configurations.
  • Toolless cover removal provides easy access to upgrades and serviceable parts, such as CPU, memory, and adapter cards.
  • Proactive Platform Alerts (including PFA and SMART alerts) for: processors, voltage regulators, memory, internal storage (SAS/SATA HDDs and SSDs), fans, power supplies, RAID controllers, and server ambient and sub-component temperatures. Alerts can be surfaced through the system IMM to managers such as Lenovo XClarity Administrator, VMware vCenter, and Microsoft System Center. These proactive alerts let you take appropriate actions in advance of possible failure, thereby increasing server uptime and application availability.
  • SSDs, with no moving parts, offer significantly better reliability than mechanical HDDs, for greater uptime.
  • The built-in XClarity Controller continuously monitors system parameters, triggers alerts, and performs recovery actions in case of failures to minimize downtime.
  • Built-in diagnostics in UEFI, using Lenovo XClarity Provisioning Manager, speed up troubleshooting tasks to reduce service time.
  • Lenovo XClarity Provisioning Manager supports diagnostics and can save service data to a USB key drive or remote CIFS share folder for troubleshooting and reduce service time.
  • Auto restart in the event of a momentary loss of AC power (based on power policy setting in the XClarity Controller service processor)
  • Support for the XClarity Administrator Mobile app running on a supported smartphone and connected to the server through the service-enabled USB port, enables additional local systems management functions.
  • Three-year or one-year customer-replaceable unit and onsite limited warranty, 9 x 5 next business day. Optional service upgrades are available.

Manageability and security

The following powerful systems management features simplify local and remote management of the ST550:

  • The server includes an XClarity Controller (XCC) to monitor server availability. Optional upgrade to XCC Advanced to provide remote control (keyboard video mouse) functions. Optional upgrade to XCC Enterprise enables the additional support for the mounting of remote media files (ISO and IMG image files), boot capture, and power capping.
  • Lenovo XClarity Administrator offers comprehensive hardware management tools that help to increase uptime, reduce costs and improve productivity through advanced server management capabilities.
  • New UEFI-based Lenovo XClarity Provisioning Manager, accessible from F1 during boot, provides system inventory information, graphical UEFI Setup, platform update function, RAID Setup wizard, operating system installation function, and diagnostic functions.
  • Support for Lenovo XClarity Energy Manager which captures real-time power and temperature data from the server and provides automated controls to lower energy costs.
  • Integrated Trusted Platform Module (TPM) 2.0 support enables advanced cryptographic functionality, such as digital signatures and remote attestation.
  • Supports Secure Boot to ensure that only a digitally signed operating system can be used. Supported with HDDs and SSDs as well as M.2 drives in the M.2 Adapter.
  • Industry-standard Advanced Encryption Standard (AES) NI support for faster, stronger encryption.
  • Intel Execute Disable Bit functionality can prevent certain classes of malicious buffer overflow attacks when combined with a supported operating system.
  • Intel Trusted Execution Technology provides enhanced security through hardware-based resistance to malicious software attacks, allowing an application to run in its own isolated space, protected from all other software running on a system.
  • Physical security measures to prevent unauthorized access: Lockable side cover to prevent access to internal components, a slot at the rear of the server for a Kensington Cable. Optional additional physical security features are a lockable front security door and a chassis intrusion switch (included in some models).

Energy efficiency

The ST550 offers the following energy-efficiency features to save energy, reduce operational costs, increase energy availability, and contribute to the green environment:

  • Energy-efficient planar components help lower operational costs.
  • High-efficiency power supplies with 80 PLUS Platinum and Titanium certifications. Energy Star 2.1 certified.
  • Intel Intelligent Power Capability powers individual processor elements on and off as needed to reduce power draw.
  • Low-voltage 1.2 V DDR4 memory DIMMs use up to 20% less energy compared to 1.35 V DDR3 DIMMs.
  • SSDs use as much as 80% less power than traditional spinning 2.5-inch HDDs.
  • The server uses hexagonal ventilation holes, which can be grouped more densely than round holes, providing more efficient airflow through the system.
  • Optional Lenovo XClarity Energy Manager provides advanced data center power notification, analysis, and policy-based management to help achieve lower heat output and reduced cooling needs.

Components and connectors

The following figure shows the front of the server.

Front view of the ThinkSystem ST550 server
Figure 2. Front view of the ThinkSystem ST550 server

The following figure shows the rear of the server.

Rear view of the ThinkSystem ST550 server
Figure 3. Rear view of the ThinkSystem ST550 server

The following figure shows the locations of key components inside the server.

Internal view of the ThinkSystem ST550 server
Figure 4. Internal view of the ThinkSystem ST550 server

Standard specifications

The following table lists the standard specifications.

Table 1. Standard specifications
Components Specification
Machine type 7X09 - 1 year warranty
7X10 - 3 year warranty
Form factor Tower or 4U Rack.
Processor One or two Intel Xeon Processor Scalable Family of processors, either Bronze, Silver, Gold or Platinum-level processors (formerly codename "Skylake"). Supports processors up to 20 cores, core speeds up to 3.6 GHz, and TDP ratings up to 125W. Two Intel Ultra Path Interconnect (UPI) links at 10.4 GT/s each.
Chipset Intel C624 "Lewisburg" chipset
Memory Up to 12 DIMM sockets (6 DIMMs per processor) supporting Lenovo TruDDR4 DIMMs at up to 2666 MHz. RDIMMs and LRDIMMs (Load Reduced DIMMs) are supported, but memory types cannot be intermixed.
Memory maximums With RDIMMs: Up to 384 GB with 12x 32 GB RDIMMs and two processors
With LRDIMMs: Up to 768 GB with 12x 64 GB LRDIMMs and two processors
Memory protection ECC, SDDC (for x4-based memory DIMMs), ADDDC (for x4-based memory DIMMs, requires Intel Xeon Gold or Platinum processors), memory mirroring, and memory sparing.
Disk drive bays

Available configurations:

  • 8, 16, or 20x 2.5-inch SAS/SATA hot-swap (optional support for NVMe drives)
  • 4 or 8x 3.5-inch SAS/SATA hot-swap
  • Both 8x 3.5-inch + 4x 2.5-inch SAS/SATA hot-swap
  • 4 or 8x 3.5-inch SATA simple-swap
Additional drive bays (except for 20-bay and hybrid configurations):
  • Two 5.25-inch drive bays for optical drives
Maximum internal storage
  • 307.2 TB with 20x 15.36TB 2.5-inch SAS hot-swap SSDs
  • 157.4 TB with 8x 12TB 3.5-inch HDDs + 4x 15.36TB 2.5-inch SSDs
  • 80 TB with 8x 10TB 3.5-inch NL SAS or NL SATA hot-swap HDDs
  • 80 TB with 8x 10TB 3.5-inch NL SAS or NL SATA simple-swap HDDs
  • Intermix of SAS and SATA is supported.
Storage controller
  • Onboard 6 Gb SATA for simple-swap drive configurations, using embedded Intel RSTe software RAID, supporting RAID 0, 1, 10, 5, 50
  • 12 Gb SAS/SATA RAID for hot-swap drive configurations:
    • RAID 530i (cacheless) supports RAID 0, 1, 10, 5, 50
    • RAID 730-8i (China only) with 1GB cache supports RAID 0, 1, 10, 5, 50
    • RAID 930-8i with 2GB flash-backed cache supports RAID 0, 1, 10, 5, 50, 6, 60
    • RAID 930-16i and 24i with 4GB flash-backed cache supports RAID 0, 1, 10, 5, 50, 6, 60
  • 12 Gb SAS/SATA non-RAID: 430-8i and 430-16i HBAs
Optical drive bays Two half-height 5.25-inch bays for optical or tape drives. Supports DVD-ROM or Multiburner. Hot-swap bays can be converted to 4x 2.5-inch hot-swap drive bays. (Not available with simple-swap drive configurations.)
Tape drive bays Two half-height 5.25-inch bays for optical or tape drives. Support for one RDX drive or LTO tape drive.
Network interfaces Two integrated Gigabit Ethernet 1000BASE-T ports (RJ-45) based on Intel X722 embedded controller (No 10/100 Mbps support)
PCI Expansion slots Up to 7 PCIe slots: 6 general purpose PCIe 3.0 slots plus one slot reserved for the M.2 adapter. General purpose slots are as follows:
  • Slot 1: PCIe 3.0 x8 (25W) FHHL
  • Slot 2: PCIe 3.0 x16 (75W); FHHL
  • Slot 3: PCIe 3.0 x16 (75W); FHFL
  • Slot 4: PCIe 3.0 x16 (x8 wired) (25W); FHFL (requires second processor)
  • Slot 5: PCIe 3.0 x16 (75W); FHFL (requires second processor)
  • Slot 6: PCIe 3.0 x8 (x4 wired) (25W); FHFL

Slots 3 and 5 support double-wide GPUs

Ports
  • Front: Two USB ports (one USB 3.0, one USB 2.0 port
  • Rear: Four USB ports (four USB 2.0, two USB 3.0), one DB-15 video, one RJ-45 systems management, two RJ-45 GbE network ports, optional serial port.
  • Internal: One internal USB 3.0 port for RDX drive
Cooling Supports ASHRAE A2 environments as well as A3/A4 with some limitations. Up to four simple-swap fans: two fans shipped standard on single processor models and three fans shipped on dual processor models. The fourth fan is N+1 redundant, except for certain configurations.
Power supply Up to two redundant hot-swap 550 W, 750 W or 1100 W High Efficiency Platinum AC power supplies, or 750 W High Efficiency Titanium AC power supplies. Also available is a 450 W fixed (non-hot-swap) power supply. In China only, all hot-swap power supplies also support 240V DC.
Hot-swap parts Hard drives, power supplies, and fans
Systems management Operator panel with status LEDs. XClarity Controller embedded management, XClarity Administrator centralized infrastructure delivery, XClarity Integrator plugins, and XClarity Energy Manager centralized server power management. Optional XClarity Controller Advanced to enable remote control functions.
Security features Power-on password, administrator's password, Trusted Platform Module (TPM), supporting TPM 1.2 or TPM 2.0. In China only, optional Trusted Cryptographic Module (TCM). Kensington cable slot. Lockable side cover. Optional lockable front security door and chassis intrusion switch (included with some models).
Video G200 graphics with 16 MB memory with 2D hardware accelerator, integrated into the XClarity Controller. Maximum resolution is 1920x1200 32bpp at 60Hz.
Operating systems supported Microsoft Windows Server 2012 R2, 2016; RHEL 6 & 7 x64; SLES 11 & 12 x64; VMware ESXi 6.0, 6.5
Limited warranty Three-year or one-year (model dependent) customer-replaceable unit and onsite limited warranty with 9x5 next business day (NBD).
Service and support Optional service upgrades are available through Lenovo Services: 4-hour or 2-hour response time, 6-hour fix time, 1-year or 2-year warranty extension, software support for Lenovo hardware and some third-party applications.
Dimensions Tower: width, without foot stands: 176 mm (6.9 in), width, with foot stands: 272 mm (10.7 in), depth: 670 mm (26.4 in), height: 438 mm (17.2 in). With rack conversion kit: Width: 482 mm (18.97 inches), depth: 670 mm (26.4 in), height: 176 mm (6.9 in)
Weight Fully configured: 36 kg (79.36 lb)

The ST550 server is shipped with the following items:

  • Documentation flyer
  • Power cords (model and region dependent)

Models

The following tables list the available models, grouped by region.

Refer to the Specifications section for information about standard features of the server.

Common to all models:

  • All models indicated as having the 750W power supply are using the Platinum power supply.

Models for Australia and New Zealand

Table 2. Models for Australia and New Zealand
Model Intel Xeon
processors†
Memory RAID Drive bays
Drives
Optical Slots Power supplies Power
cords
XCC
Level
Phys.
sec.‡
Standard models
7X10 A02AAU 1x Bronze 3104 6C 85W 1.7GHz 1x 16GB 1Rx4 Onboard RSTe 8x 3.5" SS / 8
Open bay
1x Multi burner 8 / 11 1x 750W HS No Std Yes
7X10 A02FAU 1x Bronze 3104 6C 85W 1.7GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 16
Open bay
1x DVD ROM 8 / 11 1x 750W HS No Std Yes
7X10 A02TAU 1x Bronze 3104 6C 85W 1.7GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 750W HS No Std Yes
7X10 A03EAU 1x Bronze 3104 6C 85W 1.7GHz 1x 16GB 1Rx4 RAID 530-8i 8x 3.5" HS / 8
Open bay
1x Multi burner 8 / 11 1x 750W HS No Std Yes
7X10 A03MAU 1x Bronze 3104 6C 85W 1.7GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS No Std Yes
7X10 A029AU 1x Bronze 3106 8C 85W 1.7GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 750W HS No Std Yes
7X10 A02MAU 1x Bronze 3106 8C 85W 1.7GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 16
Open bay
1x DVD ROM 8 / 11 1x 750W HS No Std Yes
7X10 A03GAU 1x Bronze 3106 8C 85W 1.7GHz 1x 16GB 1Rx4 RAID 530-8i 8x 3.5" HS / 8
Open bay
1x Multi burner 8 / 11 1x 750W HS No Std Yes
7X10 A02NAU 1x Silver 4108 8C 85W 1.8GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 16
Open bay
1x DVD ROM 8 / 11 1x 750W HS No Std Yes
7X10 A02VAU 1x Silver 4108 8C 85W 1.8GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 750W HS No Std Yes
7X10 A032AU 1x Silver 4108 8C 85W 1.8GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
3x 2.5" 300GB 10K SAS
1x Multi burner 8 / 11 2x 750W HS No Std Yes
7X10 A03DAU 1x Silver 4108 8C 85W 1.8GHz 1x 16GB 1Rx4 Onboard RSTe 8x 3.5" SS / 8
Open bay
1x Multi burner 8 / 11 1x 750W HS No Std Yes
7X10 A03HAU 1x Silver 4108 8C 85W 1.8GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS No Std Yes
7X10 A03NAU 1x Silver 4108 8C 85W 1.8GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 2x 750W HS No Std Yes
7X10 A02GAU 1x Silver 4110 8C 85W 2.1GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
3x 2.5" 300GB 10K SAS
1x Multi burner 8 / 11 2x 750W HS No Std Yes
7X10 A02LAU 1x Silver 4110 8C 85W 2.1GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 16
Open bay
1x DVD ROM 8 / 11 1x 750W HS No Std Yes
7X10 A036AU 1x Silver 4110 8C 85W 2.1GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS No Std Yes
7X10 A03FAU 1x Silver 4110 8C 85W 2.1GHz 1x 16GB 1Rx4 RAID 930-8i 8x 3.5" HS / 8*
Open bay
Open 8 / 11 1x 750W HS No Std Yes
7X10 A03QAU 1x Silver 4110 8C 85W 2.1GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 750W HS No Std Yes
7X10 A02DAU 1x Silver 4110 8C 85W 2.1GHz 4x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
2x 2.5" 600GB 10K SAS
1x Multi burner 8 / 11 2x 750W HS No Std Yes
7X10 A02EAU 1x Silver 4114 10C 85W 2.2GHz 1x 16GB 1Rx4 RAID 930-8i 8x 3.5" HS / 8*
Open bay
Open 8 / 11 1x 750W HS No Std Yes
7X10 A02JAU 1x Silver 4114 10C 85W 2.2GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS No Std Yes
7X10 A03RAU 1x Silver 4114 10C 85W 2.2GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 16
Open bay
1x DVD ROM 8 / 11 1x 750W HS No Std Yes
7X10 A02ZAU 1x Silver 4116 12C 85W 2.1GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 16
Open bay
1x DVD ROM 8 / 11 1x 750W HS No Std Yes
7X10 A038AU 1x Silver 4116 12C 85W 2.1GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS No Std Yes
7X10 A03AAU 1x Silver 4116 12C 85W 2.1GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 750W HS No Std Yes
7X10 A005AU 1x Gold 5115 10C 85W 2.4GHz 1x 16GB 1Rx4 Onboard RSTe 4x 3.5" SS / 8
Open bay
Open 8 / 11 1x 550W HS No Std Yes
7X10 A00AAU 1x Gold 5115 10C 85W 2.4GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 2x 750W HS No Std Yes
7X10 A00TAU 1x Gold 5115 10C 85W 2.4GHz 1x 16GB 1Rx4 RAID 530-8i 4x 3.5" HS / 8*
Open bay
Open 8 / 11 1x 550W HS No Std Yes
7X10 A02BAU 1x Gold 5115 10C 85W 2.4GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 2x 750W HS No Std Yes
7X10 A02RAU 1x Gold 5118 12C 105W 2.3GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x DVD ROM 8 / 11 1x 750W HS No Std Yes
7X10 A03UAU 1x Gold 5118 12C 105W 2.3GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS No Std Yes
7X10 A00KAU 1x Gold 5120 14C 105W 2.2GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS No Std Yes
7X10 A03LAU 1x Gold 5120 14C 105W 2.2GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x DVD ROM 8 / 11 1x 750W HS No Std Yes
7X10 A00MAU 1x Gold 6126T 12C 125W 2.6GHz 1x 32GB RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS No Std Yes
7X10 A011AU 1x Gold 6130T 16C 125W 2.1GHz 1x 32GB RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS No Std Yes
TopSeller models
7X10 100DAU 1x Bronze 3104 6C 85W 1.7GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS Yes Ent Yes
7X10 1000AU 1x Bronze 3106 8C 85W 1.7GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS Yes Ent Yes
7X10 100BAU 1x Bronze 3106 8C 85W 1.7GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 16
Open bay
1x Ext DVDRW 8 / 11 1x 750W HS Yes Ent Yes
7X10 1001AU 1x Silver 4108 8C 85W 1.8GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS Yes Ent Yes
7X10 1009AU 1x Silver 4108 8C 85W 1.8GHz 1x 16GB 1Rx4 RAID 930-16i 16x 2.5" HS / 16*
Open bay
Open 8 / 11 1x 1100W HS Yes Ent Yes
7X10 100EAU 1x Silver 4108 8C 85W 1.8GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS Yes Ent Yes
7X10 1002AU 1x Silver 4110 8C 85W 2.1GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS Yes Ent Yes
7X10 1008AU 1x Silver 4110 8C 85W 2.1GHz 1x 16GB 1Rx4 RAID 930-16i 16x 2.5" HS / 16*
Open bay
Open 8 / 11 1x 1100W HS Yes Ent Yes
7X10 100AAU 1x Silver 4110 8C 85W 2.1GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 16
Open bay
1x Ext DVDRW 8 / 11 1x 750W HS Yes Ent Yes
7X10 100CAU 1x Silver 4110 8C 85W 2.1GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS Yes Ent Yes
7X10 1007AU 1x Silver 4110 8C 85W 2.1GHz 2x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x Ext DVDRW 8 / 11 2x 750W Titanium Yes Ent Yes
7X10 100FAU 1x Silver 4114 10C 85W 2.2GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS Yes Ent Yes
7X10 1003AU 1x Silver 4116 12C 85W 2.1GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS Yes Ent Yes
7X10 100GAU 1x Silver 4116 12C 85W 2.1GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 1100W HS Yes Ent Yes
7X10 1004AU 1x Gold 5118 12C 105W 2.3GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 1100W HS Yes Ent Yes
7X10 100HAU 1x Gold 5118 12C 105W 2.3GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 1100W HS Yes Ent Yes
7X10 100JAU 1x Gold 6130 16C 125W 2.1GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 1100W HS Yes Ent Yes
7X10 1005AU 1x Gold 6130 16C 125W 2.1GHz 1x 32GB RAID 930-16i 16x 2.5" HS / 16*
Open bay
Open 8 / 11 1x 1100W HS Yes Ent Yes
7X10 1006AU 1x Gold 6130 16C 125W 2.1GHz 1x 32GB RAID 930-16i 16x 2.5" HS / 16*
Open bay
Open 8 / 11 1x 1100W HS Yes Ent Yes

† Processor detail: Quantity, model, core count, TDP, core frequency
** 20 drive bays includes 4x 2.5" HS drive bays with media bay conversion
* Additionally supports 4x 2.5" HS drive bays with media bay conversion
‡ Physical security includes both security door & intrusion switch

Models for South East Asian countries (ASEAN)

Table 3. Models for South East Asian countries (ASEAN)
Model Intel Xeon
processors†
Memory RAID Drive bays
Drives
Optical Slots Power supplies Power
cords
XCC
Level
Phys.
sec.‡
Standard models
7X10 A01ZSG 1x Bronze 3104 6C 85W 1.7GHz 1x 8GB RAID 530-8i 4x 3.5" HS / 8*
Open bay
Open 8 / 11 1x 550W HS No Std No
7X10 A021SG 1x Bronze 3106 8C 85W 1.7GHz 1x 8GB RAID 530-8i 4x 3.5" HS / 8*
Open bay
Open 8 / 11 1x 550W HS No Std No
7X10 A020SG 1x Silver 4110 8C 85W 2.1GHz 1x 8GB RAID 530-8i 4x 3.5" HS / 8*
Open bay
Open 8 / 11 1x 550W HS No Std No
7X10 A026SG 1x Silver 4112 4C 85W 2.6GHz 1x 8GB RAID 530-8i 4x 3.5" HS / 8*
Open bay
Open 8 / 11 1x 550W HS No Std No
7X10 A022SG 1x Silver 4114 10C 85W 2.2GHz 1x 8GB RAID 530-8i 4x 3.5" HS / 8*
Open bay
Open 8 / 11 1x 550W HS No Std No
7X10 A023SG 1x Silver 4114 10C 85W 2.2GHz 1x 8GB RAID 530-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS No Std No
7X10 A024SG 1x Silver 4116 12C 85W 2.1GHz 1x 8GB RAID 530-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS No Std No
7X10 A025SG 1x Silver 4116 12C 85W 2.1GHz 1x 8GB RAID 530-8i 4x 3.5" HS / 8*
Open bay
Open 8 / 11 1x 550W HS No Std No
7X10 A003SG 1x Gold 5115 10C 85W 2.4GHz 1x 8GB RAID 530-8i 4x 3.5" HS / 8*
Open bay
Open 8 / 11 1x 750W HS No Std No
7X10 A004SG 1x Gold 5118 12C 105W 2.3GHz 1x 8GB RAID 530-8i 4x 3.5" HS / 8*
Open bay
Open 8 / 11 1x 750W HS No Std No
7X10 A00ESG 1x Gold 5118 12C 105W 2.3GHz 1x 8GB RAID 530-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS No Std No
7X10 A00DSG 1x Gold 5120 14C 105W 2.2GHz 1x 8GB RAID 530-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS No Std No
7X10 A00GSG 1x Gold 5122 4C 105W 3.6GHz 1x 8GB RAID 530-8i 4x 3.5" HS / 8*
Open bay
Open 8 / 11 1x 750W HS No Std No
7X10 A00BSG 1x Gold 6130 16C 125W 2.1GHz 1x 8GB RAID 530-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS No Std No

† Processor detail: Quantity, model, core count, TDP, core frequency
** 20 drive bays includes 4x 2.5" HS drive bays with media bay conversion
* Additionally supports 4x 2.5" HS drive bays with media bay conversion
‡ Physical security includes both security door & intrusion switch

Models for Brazil

Table 4. Models for Brazil
Model Intel Xeon
processors†
Memory RAID Drive bays
Drives
Optical Slots Power supplies Power
cords
XCC
Level
Phys.
sec.‡
Standard models
7X10 A040BR 1x Gold 5115 10C 85W 2.4GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 2x 750W HS No Std Yes
7X10 A041BR 1x Gold 5118 12C 105W 2.3GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS No Std Yes
7X10 A042BR 1x Gold 5118 12C 105W 2.3GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x DVD ROM 8 / 11 1x 750W HS No Std Yes
7X10 A03YBR 1x Gold 5120 14C 105W 2.2GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x DVD ROM 8 / 11 1x 750W HS No Std Yes

† Processor detail: Quantity, model, core count, TDP, core frequency
** 20 drive bays includes 4x 2.5" HS drive bays with media bay conversion
* Additionally supports 4x 2.5" HS drive bays with media bay conversion
‡ Physical security includes both security door & intrusion switch

Models for EMEA countries

Table 5. Models for EMEA countries
Model Intel Xeon
processors†
Memory RAID Drive bays
Drives
Optical Slots Power supplies Power
cords
XCC
Level
Phys.
sec.‡
Standard models
7X10 A01UEA 1x Bronze 3104 6C 85W 1.7GHz 1x 16GB 1Rx4 Onboard RSTe 8x 3.5" SS / 8
Open bay
1x Multi burner 8 / 11 1x 750W HS No Std Yes
7X10 A01XEA 1x Bronze 3104 6C 85W 1.7GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 16
Open bay
1x DVD ROM 8 / 11 1x 750W HS No Std Yes
7X10 A01REA 1x Bronze 3106 8C 85W 1.7GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 16
Open bay
1x DVD ROM 8 / 11 1x 750W HS No Std Yes
7X10 A01TEA 1x Silver 4108 8C 85W 1.8GHz 1x 16GB 1Rx4 Onboard RSTe 8x 3.5" SS / 8
Open bay
1x Multi burner 8 / 11 1x 750W HS No Std Yes
7X10 A01VEA 1x Silver 4108 8C 85W 1.8GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 16
Open bay
1x DVD ROM 8 / 11 1x 750W HS No Std Yes
7X10 A01YEA 1x Silver 4110 8C 85W 2.1GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 16
Open bay
1x DVD ROM 8 / 11 1x 750W HS No Std Yes
7X10 A01WEA 1x Silver 4114 10C 85W 2.2GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 16
Open bay
1x DVD ROM 8 / 11 1x 750W HS No Std Yes
7X10 A01SEA 1x Silver 4116 12C 85W 2.1GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 16
Open bay
1x DVD ROM 8 / 11 1x 750W HS No Std Yes
7X10 A02UEA 1x Gold 5118 12C 105W 2.3GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x DVD ROM 8 / 11 1x 750W HS No Std Yes
7X10 A00VEA 1x Gold 5120 14C 105W 2.2GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x DVD ROM 8 / 11 1x 750W HS No Std Yes
TopSeller models
7X10 A01HEA 1x Bronze 3104 6C 85W 1.7GHz 1x 16GB 1Rx4 RAID 530-8i 8x 3.5" HS / 8
Open bay
1x Multi burner 8 / 11 1x 750W HS No Std Yes
7X10 A01NEA 1x Bronze 3104 6C 85W 1.7GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 750W HS No Std Yes
7X10 A01QEA 1x Bronze 3104 6C 85W 1.7GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS No Std Yes
7X10 A01DEA 1x Bronze 3106 8C 85W 1.7GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 750W HS No Std Yes
7X10 A01FEA 1x Bronze 3106 8C 85W 1.7GHz 1x 16GB 1Rx4 RAID 530-8i 8x 3.5" HS / 8
Open bay
1x Multi burner 8 / 11 1x 750W HS No Std Yes
7X10 A039EA 1x Bronze 3106 8C 85W 1.7GHz 1x 16GB 1Rx4 RAID 530-8i 8x 3.5" HS / 8*
2x 3.5" 1TB 7.2K SATA
Open 8 / 11 1x 550W HS No Std Yes
7X10 A03KEA 1x Bronze 3106 8C 85W 1.7GHz 1x 16GB 1Rx4 RAID 530-8i 4x 3.5" HS / 8
Open bay
1x Multi burner 8 / 11 1x 550W HS No Std Yes
7X10 A018EA 1x Silver 4108 8C 85W 1.8GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 750W HS No Std Yes
7X10 A019EA 1x Silver 4108 8C 85W 1.8GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
3x 2.5" 300GB 10K SAS
1x Multi burner 8 / 11 2x 750W HS No Std Yes
7X10 A01CEA 1x Silver 4108 8C 85W 1.8GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 2x 750W HS No Std Yes
7X10 A01LEA 1x Silver 4108 8C 85W 1.8GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS No Std Yes
7X10 A017EA 1x Silver 4110 8C 85W 2.1GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 750W HS No Std Yes
7X10 A01AEA 1x Silver 4110 8C 85W 2.1GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
3x 2.5" 300GB 10K SAS
1x Multi burner 8 / 11 2x 750W HS No Std Yes
7X10 A01EEA 1x Silver 4110 8C 85W 2.1GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS No Std Yes
7X10 A01JEA 1x Silver 4110 8C 85W 2.1GHz 1x 16GB 1Rx4 RAID 930-8i 8x 3.5" HS / 8*
Open bay
Open 8 / 11 1x 750W HS No Std Yes
7X10 A02YEA 1x Silver 4110 8C 85W 2.1GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 550W HS No Std Yes
7X10 A03VEA 1x Silver 4110 8C 85W 2.1GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
2x 2.5" 300GB 10K SAS
1x Multi burner 8 / 11 2x 550W HS No Std Yes
7X10 A01KEA 1x Silver 4110 8C 85W 2.1GHz 4x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
2x 2.5" 600GB 10K SAS
1x Multi burner 8 / 11 2x 750W HS No Std Yes
7X10 A03ZEA 1x Silver 4110 8C 85W 2.1GHz 4x 32GB RAID 930-8i 8x 2.5" HS / 16
3x 2.5" 900GB 10K SAS
1x Multi burner 8 / 11 2x 750W HS No Std Yes
7X10 A01MEA 1x Silver 4114 10C 85W 2.2GHz 1x 16GB 1Rx4 RAID 930-8i 8x 3.5" HS / 8*
Open bay
Open 8 / 11 1x 750W HS No Std Yes
7X10 A01PEA 1x Silver 4114 10C 85W 2.2GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS No Std Yes
7X10 A01BEA 1x Silver 4116 12C 85W 2.1GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS No Std Yes
7X10 A01GEA 1x Silver 4116 12C 85W 2.1GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 750W HS No Std Yes
7X10 A00HEA 1x Gold 5115 10C 85W 2.4GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 2x 750W HS No Std Yes
7X10 A013EA 1x Gold 5115 10C 85W 2.4GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS No Std Yes
7X10 A02HEA 1x Gold 5118 12C 105W 2.3GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS No Std Yes
7X10 A006EA 1x Gold 5122 4C 105W 3.6GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 750W HS No Std Yes

† Processor detail: Quantity, model, core count, TDP, core frequency
** 20 drive bays includes 4x 2.5" HS drive bays with media bay conversion
* Additionally supports 4x 2.5" HS drive bays with media bay conversion
‡ Physical security includes both security door & intrusion switch

Models for Hong Kong, Taiwan, Korea (HTK)

Table 6. Models for Hong Kong, Taiwan, Korea (HTK)
Model Intel Xeon
processors†
Memory RAID Drive bays
Drives
Optical Slots Power supplies Power
cords
XCC
Level
Phys.
sec.‡
Standard models
7X10 A010CN 1x Gold 5115 10C 85W 2.4GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS Yes Std No
7X10 A00YCN 1x Gold 5118 12C 105W 2.3GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS Yes Std No
7X10 A00RCN 1x Gold 5120 14C 105W 2.2GHz 1x 16GB 1Rx4 RAID 930-8i 4x 3.5" HS / 8*
Open bay
Open 8 / 11 1x 750W HS Yes Std No
7X10 A00WCN 1x Gold 5120 14C 105W 2.2GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS Yes Std No
7X10 A00SCN 1x Gold 5122 4C 105W 3.6GHz 1x 16GB 1Rx4 RAID 930-8i 4x 3.5" HS / 8*
Open bay
Open 8 / 11 1x 750W HS Yes Std No
7X10 A014CN 1x Gold 5122 4C 105W 3.6GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS Yes Std No
7X10 A00QCN 1x Gold 6126 12C 125W 2.6GHz 1x 16GB 1Rx4 RAID 930-8i 4x 3.5" HS / 8*
Open bay
Open 8 / 11 1x 750W HS Yes Std No
7X10 A00ZCN 1x Gold 6126 12C 125W 2.6GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS Yes Std No
7X10 A012CN 1x Gold 6126 12C 125W 2.6GHz 1x 8GB RAID 530-8i 4x 3.5" HS / 8*
Open bay
Open 8 / 11 1x 750W HS Yes Std No
7X10 A00PCN 1x Gold 6130 16C 125W 2.1GHz 1x 16GB 1Rx4 RAID 930-8i 4x 3.5" HS / 8*
Open bay
Open 8 / 11 1x 750W HS Yes Std No
7X10 A00XCN 1x Gold 6130 16C 125W 2.1GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS Yes Std No
TopSeller models
7X10 A06BCN 1x Bronze 3104 6C 85W 1.7GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS No Std No
7X10 A06DCN 1x Bronze 3104 6C 85W 1.7GHz 1x 16GB 1Rx4 RAID 930-8i 8x 3.5" HS / 8*
Open bay
Open 8 / 11 1x 750W HS No Std No
7X10 A06CCN 1x Bronze 3106 8C 85W 1.7GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS No Std No
7X10 A06ECN 1x Bronze 3106 8C 85W 1.7GHz 1x 16GB 1Rx4 RAID 930-8i 8x 3.5" HS / 8*
Open bay
Open 8 / 11 1x 750W HS No Std No
7X10 A063CN 1x Silver 4110 8C 85W 2.1GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS No Std No
7X10 A067CN 1x Silver 4110 8C 85W 2.1GHz 1x 16GB 1Rx4 RAID 930-8i 8x 3.5" HS / 8*
Open bay
Open 8 / 11 1x 750W HS No Std No
7X10 A066CN 1x Silver 4112 4C 85W 2.6GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS No Std No
7X10 A06ACN 1x Silver 4112 4C 85W 2.6GHz 1x 16GB 1Rx4 RAID 930-8i 4x 3.5" HS / 8*
Open bay
Open 8 / 11 1x 750W HS No Std No
7X10 A064CN 1x Silver 4114 10C 85W 2.2GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS No Std No
7X10 A068CN 1x Silver 4114 10C 85W 2.2GHz 1x 16GB 1Rx4 RAID 930-8i 8x 3.5" HS / 8*
Open bay
Open 8 / 11 1x 750W HS No Std No
7X10 A065CN 1x Silver 4116 12C 85W 2.1GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 20**
Open bay
Open 8 / 11 1x 750W HS No Std No
7X10 A069CN 1x Silver 4116 12C 85W 2.1GHz 1x 16GB 1Rx4 RAID 930-8i 8x 3.5" HS / 8*
Open bay
Open 8 / 11 1x 750W HS No Std No

† Processor detail: Quantity, model, core count, TDP, core frequency
** 20 drive bays includes 4x 2.5" HS drive bays with media bay conversion
* Additionally supports 4x 2.5" HS drive bays with media bay conversion
‡ Physical security includes both security door & intrusion switch

Models for India

Table 7. Models for India
Model Intel Xeon
processors†
Memory RAID Drive bays
Drives
Optical Slots Power supplies Power
cords
XCC
Level
Phys.
sec.‡
Standard models
7X10 A03SSG 1x Bronze 3104 6C 85W 1.7GHz 1x 8GB Onboard RSTe 4x 3.5" SS / 8
Open bay
1x Multi burner 8 / 11 1x 550W HS No Std No
7X10 A03BSG 1x Bronze 3106 8C 85W 1.7GHz 1x 16GB 1Rx4 RAID 530-8i 4x 3.5" HS / 8
Open bay
1x Multi burner 8 / 11 1x 550W HS No Std No
7X10 A03TSG 1x Bronze 3106 8C 85W 1.7GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 550W HS No Std No
7X10 A02CSG 1x Bronze 3106 8C 85W 1.7GHz 1x 8GB RAID 530-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 550W HS No Std No
7X10 A02SSG 1x Bronze 3106 8C 85W 1.7GHz 1x 8GB Onboard RSTe 4x 3.5" SS / 8
Open bay
1x Multi burner 8 / 11 1x 550W HS No Std No
7X10 A033SG 1x Bronze 3106 8C 85W 1.7GHz 1x 8GB RAID 530-8i 4x 3.5" HS / 8
Open bay
1x Multi burner 8 / 11 1x 550W HS No Std No
7X10 A027SG 1x Silver 4108 8C 85W 1.8GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 550W HS No Std No
7X10 A03WSG 1x Silver 4108 8C 85W 1.8GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 550W HS No Std No
7X10 A034SG 1x Silver 4108 8C 85W 1.8GHz 1x 8GB RAID 530-8i 4x 3.5" HS / 8
Open bay
1x Multi burner 8 / 11 1x 550W HS No Std No
7X10 A037SG 1x Silver 4110 8C 85W 2.1GHz 1x 8GB RAID 530-8i 4x 3.5" HS / 8
Open bay
1x Multi burner 8 / 11 1x 550W HS No Std No
7X10 A02QSG 1x Silver 4114 10C 85W 2.2GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 550W HS No Std No
7X10 A02WSG 1x Silver 4114 10C 85W 2.2GHz 1x 16GB 1Rx4 RAID 530-8i 4x 3.5" HS / 8
Open bay
1x Multi burner 8 / 11 1x 550W HS No Std No
7X10 A03CSG 1x Silver 4114 10C 85W 2.2GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 550W HS No Std No
7X10 A02KSG 1x Silver 4116 12C 85W 2.1GHz 1x 16GB 1Rx4 RAID 930-16i 16x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 750W HS No Std No
7X10 A030SG 1x Silver 4116 12C 85W 2.1GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 550W HS No Std No
7X10 A03XSG 1x Silver 4116 12C 85W 2.1GHz 1x 16GB 1Rx4 RAID 530-8i 4x 3.5" HS / 8
Open bay
1x Multi burner 8 / 11 1x 550W HS No Std No
7X10 A02XSG 1x Silver 4116 12C 85W 2.1GHz 1x 8GB RAID 530-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 550W HS No Std No
7X10 A015SG 1x Gold 5115 10C 85W 2.4GHz 1x 16GB 1Rx4 RAID 530-8i 4x 3.5" HS / 8
Open bay
1x Multi burner 8 / 11 1x 550W HS No Std No
7X10 A016SG 1x Gold 5115 10C 85W 2.4GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 550W HS No Std No
7X10 A001SG 1x Gold 5115 10C 85W 2.4GHz 1x 8GB RAID 530-8i 4x 3.5" HS / 8
Open bay
1x Multi burner 8 / 11 1x 550W HS No Std No
7X10 A00FSG 1x Gold 5115 10C 85W 2.4GHz 1x 8GB Onboard RSTe 4x 3.5" SS / 8
Open bay
1x Multi burner 8 / 11 1x 550W HS No Std No
7X10 A00LSG 1x Gold 5118 12C 105W 2.3GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 550W HS No Std No
7X10 A008SG 1x Gold 5120 14C 105W 2.2GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 550W HS No Std No
7X10 A00USG 1x Gold 5120 14C 105W 2.2GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 750W HS No Std No
7X10 A007SG 1x Gold 6126 12C 125W 2.6GHz 1x 16GB 1Rx4 RAID 930-16i 16x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 750W HS No Std No
7X10 A002SG 1x Gold 6130 16C 125W 2.1GHz 1x 16GB 1Rx4 RAID 930-16i 16x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 750W HS No Std No
7X10 A00NSG 1x Gold 6130 16C 125W 2.1GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 750W HS No Std No

† Processor detail: Quantity, model, core count, TDP, core frequency
** 20 drive bays includes 4x 2.5" HS drive bays with media bay conversion
* Additionally supports 4x 2.5" HS drive bays with media bay conversion
‡ Physical security includes both security door & intrusion switch

Models for Japan

Table 8. Models for Japan
Model Intel Xeon
processors†
Memory RAID Drive bays
Drives
Optical Slots Power supplies Power
cords
XCC
Level
Phys.
sec.‡
Standard models
7X10 A009JP 1x Gold 6130 16C 125W 2.1GHz 2x 16GB 1Rx4 RAID 930-16i 16x 2.5" HS / 16
Open bay
1x DVD ROM 8 / 11 1x 1100W HS No Adv Yes
Topseller Models
7X10 A044JP 1x Bronze 3104 6C 85W 1.7GHz 2x 16GB 1Rx4 RAID 930-8i 8x 3.5" HS / 8
Open bay
1x DVD ROM 8 / 11 1x 550W HS No Adv Yes
7X10 A045JP 1x Bronze 3106 8C 85W 1.7GHz 2x 16GB 1Rx4 RAID 930-16i 16x 2.5" HS / 16
Open bay
1x DVD ROM 8 / 11 1x 750W HS No Adv Yes
7X10 A043JP 1x Silver 4110 8C 85W 2.1GHz 2x 16GB 1Rx4 RAID 930-16i 16x 2.5" HS / 16
Open bay
1x DVD ROM 8 / 11 1x 1100W HS No Adv Yes
7X10 A046JP 1x Silver 4110 8C 85W 2.1GHz 2x 16GB 1Rx4 RAID 930-8i 8x 3.5" HS / 8
Open bay
1x DVD ROM 8 / 11 1x 1100W HS No Adv Yes
7X10 A047JP 1x Silver 4114 10C 85W 2.2GHz 2x 16GB 1Rx4 RAID 930-8i 8x 3.5" HS / 8
Open bay
1x DVD ROM 8 / 11 1x 750W HS No Adv Yes
7X10 A048JP 1x Gold 6130 16C 125W 2.1GHz 2x 16GB 1Rx4 RAID 930-24i Other
Open bay
No support 8 / 11 1x 1100W HS No Adv Yes
7X10 A049JP 1x Gold 6130 16C 125W 2.1GHz 2x 16GB 1Rx4 RAID 930-16i 16x 2.5" HS / 16
Open bay
1x DVD ROM 8 / 11 1x 1100W HS No Adv Yes

† Processor detail: Quantity, model, core count, TDP, core frequency
** 20 drive bays includes 4x 2.5" HS drive bays with media bay conversion
* Additionally supports 4x 2.5" HS drive bays with media bay conversion
‡ Physical security includes both security door & intrusion switch

Models for Latin American countries (except Brazil)

Table 9. Models for Latin American countries (except Brazil)
Model Intel Xeon
processors†
Memory RAID Drive bays
Drives
Optical Slots Power supplies Power
cords
XCC
Level
Phys.
sec.‡
Standard models
7X10 A05HLA 1x Silver 4114 10C 85W 2.2GHz 1x 8GB RAID 530-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 750W HS Yes Std No
7X10 A05LLA 1x Silver 4114 10C 85W 2.2GHz 1x 8GB RAID 530-8i 4x 3.5" HS / 8
Open bay
1x Multi burner 8 / 11 1x 750W HS Yes Std No
7X10 A04RLA 1x Gold 5115 10C 85W 2.4GHz 1x 16GB 1Rx4 RAID 930-8i 4x 3.5" HS / 8
Open bay
1x Multi burner 8 / 11 1x 750W HS Yes Std No
7X10 A05FLA 1x Gold 5115 10C 85W 2.4GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 750W HS Yes Std No
7X10 A04XLA 1x Gold 5118 12C 105W 2.3GHz 1x 16GB 1Rx4 RAID 930-8i 4x 3.5" HS / 8
Open bay
1x Multi burner 8 / 11 1x 750W HS Yes Std No
7X10 A05ALA 1x Gold 5118 12C 105W 2.3GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 750W HS Yes Std No
7X10 A05GLA 1x Gold 5120 14C 105W 2.2GHz 1x 16GB 1Rx4 RAID 930-8i 4x 3.5" HS / 8
Open bay
1x Multi burner 8 / 11 1x 750W HS Yes Std No
7X10 A05KLA 1x Gold 5120 14C 105W 2.2GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 750W HS Yes Std No
7X10 A04KLA 1x Gold 6130 16C 125W 2.1GHz 1x 16GB 1Rx4 RAID 930-8i 4x 3.5" HS / 8
Open bay
1x Multi burner 8 / 11 1x 750W HS Yes Std No
7X10 A056LA 1x Gold 6130 16C 125W 2.1GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 750W HS Yes Std No
7X10 A054LA 1x Gold 6138 20C 125W 2.0GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 750W HS Yes Std No
7X10 A059LA 1x Gold 6138 20C 125W 2.0GHz 1x 16GB 1Rx4 RAID 930-8i 4x 3.5" HS / 8
Open bay
1x Multi burner 8 / 11 1x 750W HS Yes Std No
TopSeller models
7X10 A057LA 1x Bronze 3104 6C 85W 1.7GHz 1x 8GB RAID 530-8i 4x 3.5" HS / 8
Open bay
1x Multi burner 8 / 11 1x 750W HS Yes Std No
7X10 A05CLA 1x Bronze 3104 6C 85W 1.7GHz 1x 8GB RAID 530-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 750W HS Yes Std No
7X10 A04SLA 1x Bronze 3106 8C 85W 1.7GHz 1x 8GB RAID 530-8i 4x 3.5" HS / 8
Open bay
1x Multi burner 8 / 11 1x 750W HS Yes Std No
7X10 A055LA 1x Bronze 3106 8C 85W 1.7GHz 1x 8GB RAID 530-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 750W HS Yes Std No
7X10 A04GLA 1x Silver 4108 8C 85W 1.8GHz 1x 16GB 1Rx4 RAID 930-8i 8x 3.5" HS / 8
2x 3.5" 2TB 7.2K SAS
1x Multi burner 8 / 11 2x 750W HS Yes Adv No
7X10 A04JLA 1x Silver 4108 8C 85W 1.8GHz 1x 16GB 1Rx4 RAID 930-8i 8x 3.5" HS / 8
2x 3.5" 600GB 15K SAS
1x Multi burner 8 / 11 2x 750W HS Yes Adv No
7X10 A051LA 1x Silver 4108 8C 85W 1.8GHz 1x 16GB 1Rx4 RAID 930-8i 8x 3.5" HS / 8
2x 3.5" 2TB 7.2K SAS
1x Multi burner 8 / 11 2x 750W HS Yes Adv No
7X10 A053LA 1x Silver 4108 8C 85W 1.8GHz 1x 16GB 1Rx4 RAID 930-8i 8x 3.5" HS / 8
2x 3.5" 600GB 15K SAS
1x Multi burner 8 / 11 2x 750W HS Yes Adv No
7X10 A05BLA 1x Silver 4108 8C 85W 1.8GHz 1x 16GB 1Rx4 RAID 930-8i 8x 3.5" HS / 8
2x 3.5" 4TB 7.2K SAS
1x Multi burner 8 / 11 2x 750W HS Yes Adv No
7X10 A04WLA 1x Silver 4108 8C 85W 1.8GHz 1x 8GB RAID 530-8i 4x 3.5" HS / 8
Open bay
1x Multi burner 8 / 11 1x 750W HS Yes Std No
7X10 A052LA 1x Silver 4108 8C 85W 1.8GHz 1x 8GB RAID 530-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 750W HS Yes Std No
7X10 100KLA 1x Silver 4110 8C 85W 2.1GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 750W HS Yes Std No
7X10 100LLA 1x Silver 4110 8C 85W 2.1GHz 1x 16GB 1Rx4 RAID 930-16i 16x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 2x 750W HS Yes Std No
7X10 A04LLA 1x Silver 4110 8C 85W 2.1GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
2x 2.5" 900GB 10K SAS
1x Multi burner 8 / 11 2x 750W HS Yes Adv No
7X10 A04QLA 1x Silver 4110 8C 85W 2.1GHz 1x 16GB 1Rx4 RAID 930-8i 8x 3.5" HS / 8
2x 3.5" 2TB 7.2K SAS
1x Multi burner 8 / 11 2x 750W HS Yes Adv No
7X10 A04ELA 1x Silver 4110 8C 85W 2.1GHz 1x 8GB RAID 530-8i 4x 3.5" HS / 8
Open bay
1x Multi burner 8 / 11 1x 750W HS Yes Std No
7X10 A05JLA 1x Silver 4110 8C 85W 2.1GHz 1x 8GB RAID 530-8i 8x 2.5" HS / 16
Open bay
1x Multi burner 8 / 11 1x 750W HS Yes Std No
7X10 A058LA 1x Silver 4110 8C 85W 2.1GHz 2x 16GB 1Rx4 RAID 930-8i 8x 3.5" HS / 8
3x 3.5" 4TB 7.2K SAS
1x Multi burner 8 / 11 2x 750W HS Yes Adv No
7X10 A05ELA 1x Silver 4110 8C 85W 2.1GHz 2x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
3x 2.5" 900GB 10K SAS
1x Multi burner 8 / 11 2x 750W HS Yes Adv No
7X10 A05DLA 1x Silver 4114 10C 85W 2.2GHz 2x 16GB 1Rx4 RAID 930-8i 8x 3.5" HS / 8
3x 3.5" 600GB 15K SAS
1x Multi burner 8 / 11 2x 750W HS Yes Adv No

† Processor detail: Quantity, model, core count, TDP, core frequency
** 20 drive bays includes 4x 2.5" HS drive bays with media bay conversion
* Additionally supports 4x 2.5" HS drive bays with media bay conversion
‡ Physical security includes both security door & intrusion switch

Models for USA and Canada

Table 10. Models for USA and Canada
Model Intel Xeon
processors†
Memory RAID Drive bays
Drives
Optical Slots Power supplies Power
cords
XCC
Level
Phys.
sec.‡
Standard models
7X10 A04NNA 1x Bronze 3104 6C 85W 1.7GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 16
Open bay
1x DVD ROM 8 / 11 1x 750W HS Yes Std Yes
7X10 A04UNA 1x Bronze 3104 6C 85W 1.7GHz 1x 16GB 1Rx4 Onboard RSTe 8x 3.5" SS / 8
Open bay
1x Multi burner 8 / 11 1x 750W HS Yes Std Yes
7X10 A04PNA 1x Bronze 3106 8C 85W 1.7GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 16
Open bay
1x DVD ROM 8 / 11 1x 750W HS Yes Std Yes
7X10 A04DNA 1x Silver 4108 8C 85W 1.8GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 16
Open bay
1x DVD ROM 8 / 11 1x 750W HS Yes Std Yes
7X10 A04VNA 1x Silver 4108 8C 85W 1.8GHz 1x 16GB 1Rx4 Onboard RSTe 8x 3.5" SS / 8
Open bay
1x Multi burner 8 / 11 1x 750W HS Yes Std Yes
7X10 A04FNA 1x Silver 4110 8C 85W 2.1GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 16
Open bay
1x DVD ROM 8 / 11 1x 750W HS Yes Std Yes
7X10 A04HNA 1x Silver 4114 10C 85W 2.2GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 16
Open bay
1x DVD ROM 8 / 11 1x 750W HS Yes Std Yes
7X10 A04TNA 1x Silver 4116 12C 85W 2.1GHz 1x 16GB 1Rx4 RAID 530-8i 8x 2.5" HS / 16
Open bay
1x DVD ROM 8 / 11 1x 750W HS Yes Std Yes
7X10 A04YNA 1x Gold 5118 12C 105W 2.3GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x DVD ROM 8 / 11 1x 750W HS Yes Std Yes
7X10 A04ZNA 1x Gold 5120 14C 105W 2.2GHz 1x 16GB 1Rx4 RAID 930-8i 8x 2.5" HS / 16
Open bay
1x DVD ROM 8 / 11 1x 750W HS Yes Std Yes
TopSeller models
7X10 A03PNA 1x Bronze 3106 8C 85W 1.7GHz 1x 16GB 1Rx4 RAID 530-8i 4x 3.5" HS / 8*
Open bay
Open 8 / 11 1x 750W HS Yes Ent No
7X10 A028NA 1x Silver 4110 8C 85W 2.1GHz 1x 16GB 1Rx4 RAID 530-8i 8x 3.5" HS / 8*
Open bay
Open 8 / 11 1x 750W HS Yes Ent No
7X10 A02PNA 1x Silver 4116 12C 85W 2.1GHz 1x 32GB RAID 930-8i 8x 3.5" HS / 8*
Open bay
Open 8 / 11 1x 750W HS Yes Ent No

† Processor detail: Quantity, model, core count, TDP, core frequency
** 20 drive bays includes 4x 2.5" HS drive bays with media bay conversion
* Additionally supports 4x 2.5" HS drive bays with media bay conversion
‡ Physical security includes both security door & intrusion switch

Processor options

The ST550 supports the Bronze, Silver, Gold, and Platinum level processors in the Intel Xeon Processor Scalable Family. The server supports the processor options that are listed in the following table. The server supports up to two processors.

Tip: The option part numbers listed in the table below includes the processor heatsink and an additional system fan.

All supported processors have the following characteristics:

  • 14 nm process technology
  • Six DDR4 memory channels
  • 48 PCIe 3.0 I/O lanes
  • 1 MB L2 cache
  • 1.375 MB L3 cache per core (except where larger, as noted with ** in the table below)
  • Intel Hyper-Threading Technology (except Bronze processors)
  • Intel Turbo Boost Technology 2.0 (except Bronze processors)
  • Intel Advanced Vector Extensions 512 (AVX-512)
  • Two Intel Ultra Path Interconnect (UPI) links at up to 10.4 GT/s (replaces QPI)

Processors with the T suffix are those that have more robust thermal characteristics (higher T-case).

Table 11. Processor options
Part
number
Feature
code
Description Memory
speed
L3 cache** UPI
speed
HT TB
4XG7A07219 B0QW Intel Xeon Bronze 3104 6C 85W 1.7GHz 2133 MHz 8.25 MB 9.6 GT/s No No
4XG7A07218 B0QV Intel Xeon Bronze 3106 8C 85W 1.7GHz 2133 MHz 11 MB 9.6 GT/s No No
4XG7A07217 B0QQ Intel Xeon Silver 4108 8C 85W 1.8GHz 2400 MHz 11 MB 9.6 GT/s Yes Yes
4XG7A07216 B0QY Intel Xeon Silver 4109T 8C 70W 2.0GHz 2400 MHz 11 MB 9.6 GT/s Yes Yes
4XG7A07215 B0QT Intel Xeon Silver 4110 8C 85W 2.1GHz 2400 MHz 11 MB 9.6 GT/s Yes Yes
4XG7A07214 B0QP Intel Xeon Silver 4112 4C 85W 2.6GHz 2400 MHz 8.5 MB** 9.6 GT/s Yes Yes
4XG7A07213 B0QR Intel Xeon Silver 4114 10C 85W 2.2GHz 2400 MHz 13.75 MB 9.6 GT/s Yes Yes
4XG7A09063 B0Y8 Intel Xeon Silver 4114T 10C 85W 2.2GHz 2400 MHz 13.75 MB 9.6 GT/s Yes Yes
4XG7A07212 B0QU Intel Xeon Silver 4116 12C 85W 2.1GHz 2400 MHz 16.5 MB 9.6 GT/s Yes Yes
4XG7A09062 B0YA Intel Xeon Silver 4116T 12C 85W 2.1GHz 2400 MHz 16.5 MB 9.6 GT/s Yes Yes
7XG7A05790 AXSZ Intel Xeon Gold 5115 10C 85W 2.4GHz 2400 MHz 13.75 MB 10.4 GT/s Yes Yes
4XG7A09086 B202 Intel Xeon Gold 5117 14C 105W 2.0GHz 2400 MHz 19.25 MB 10.4 GT/s Yes Yes
7XG7A05789 AXT0 Intel Xeon Gold 5118 12C 105W 2.3GHz 2400 MHz 16.5 MB 10.4 GT/s Yes Yes
4XG7A09061  B0Y7 Intel Xeon Gold 5119T 14C 85W 1.9GHz 2400 MHz 19.25 MB 10.4 GT/s Yes Yes
7XG7A05788 AXT1 Intel Xeon Gold 5120 14C 105W 2.2GHz 2400 MHz 19.25 MB 10.4 GT/s Yes Yes
7XG7A05787 AXT2 Intel Xeon Gold 5120T 14C 105W 2.2GHz 2400 MHz 19.25 MB 10.4 GT/s Yes Yes
7XG7A05786 AXT3 Intel Xeon Gold 5122 4C 105W 3.6GHz 2666 MHz* 16.5 MB** 10.4 GT/s Yes Yes
7XG7A05785 AXT4 Intel Xeon Gold 6126 12C 125W 2.6GHz 2666 MHz 19.25 MB** 10.4 GT/s Yes Yes
7XG7A05784 AXT5 Intel Xeon Gold 6126T 12C 125W 2.6GHz 2666 MHz 19.25 MB** 10.4 GT/s Yes Yes
4XG7A09060 AWEB Intel Xeon Gold 6128 6C 115W 3.4GHz 2666 MHz 19.25 MB** 10.4 GT/s Yes Yes
7XG7A05783 AXT6 Intel Xeon Gold 6130 16C 125W 2.1GHz 2666 MHz 22 MB 10.4 GT/s Yes Yes
7XG7A05782 AXT7 Intel Xeon Gold 6130T 16C 125W 2.1GHz 2666 MHz 22 MB 10.4 GT/s Yes Yes
4XG7A07211 B0QS Intel Xeon Gold 6138 20C 125W 2.0GHz 2666 MHz 27.5 MB 10.4 GT/s Yes Yes
4XG7A07210 B0QX Intel Xeon Gold 6138T 20C 125W 2.0GHz 2666 MHz 27.5 MB 10.4 GT/s Yes Yes
4XG7A07209 B0QZ Intel Xeon Platinum 8153 16C 125W 2.0GHz 2666 MHz 22 MB 10.4 GT/s Yes Yes
4XG7A07208 B0QN Intel Xeon Platinum 8156 4C 105W 3.6GHz 2666 MHz 16.5 MB** 10.4 GT/s Yes Yes

* All Gold 5000-level processors, except the 5122, support 2400 MHz memory speed. The 5122 processor supports 2666 MHz.
** L3 cache is 1.375 MB per core except with the processor indicated with **, where the cache size is larger

Memory options

The ST550 server supports Lenovo TruDDR4 memory. TruDDR4 memory uses the highest-quality components sourced from Tier 1 DRAM suppliers and only memory that meets strict requirements is selected. It is compatibility-tested and tuned to maximize performance and reliability.

TruDDR4 memory has a unique signature programmed into the DIMM, which enables ThinkSystem servers to verify whether the memory installed is qualified and supported. From a service and support standpoint, TruDDR4 memory automatically assumes the system's warranty, and service and support provided worldwide.

The ST550 supports up to 6 DIMMs per processor, for a total of 12 DIMMs when two processors are installed. Each processor has six memory channels, and supports one DIMM per channel.

All DIMMs operate at a speed of 2666 MHz. However, if the processor selected has a lower memory bus speed (eg 2400 MHz or 2133 MHz - see the Processor options table), then all DIMMs will operate at that lower speed.

The following table lists the memory options that are available for the ST550 server.

Table 12. Memory options
Part
number
Feature
code
Description Maximum
supported
RDIMMs
7X77A01301 AUU1 ThinkSystem 8GB TruDDR4 2666 MHz (1Rx8 1.2V) RDIMM 12 (6 per processor)
7X77A01302 AUNB ThinkSystem 16GB TruDDR4 2666 MHz (1Rx4 1.2V) RDIMM 12 (6 per processor)
7X77A01304 AUND ThinkSystem 32GB TruDDR4 2666 MHz (2Rx4 1.2V) RDIMM 12 (6 per processor)
LRDIMMs
7X77A01305 AUNE ThinkSystem 64GB TruDDR4 2666 MHz (4Rx4 1.2V) LRDIMM 12 (6 per processor)

The following rules apply when selecting the memory configuration:

  • The server supports RDIMMs and LRDIMMs.i
  • Mixing RDIMMs and LRDIMMs is not supported.
  • Mixing x4 and x8 DIMMs is supported.
  • For best performance, populate memory DIMMs in quantities of 6 per processor, so that all memory channels are used.

The following memory protection technologies are supported:

  • ECC
  • SDDC (for x4-based memory DIMMs; look for "x4" in the DIMM description)
  • ADDDC (for x4-based memory DIMMs; Gold and Platinum processors only)
  • Memory channel mirroring
  • Memory rank sparing

If memory channel mirroring is used, then DIMMs must be installed in pairs (minimum of one pair per processor), and both DIMMs in a pair must be identical in type and size. 50% of the installed capacity is available to the operating system.

If memory rank sparing is used, then a minimum of one quad-rank DIMM or two single-rank or dual-rank DIMMs must be installed per populated channel (the DIMMs do not need to be identical). In rank sparing mode, one rank of a DIMM in each populated channel is reserved as spare memory. The largest rank in the channel will be automatically selected as the spare rank. The amount of memory available to the operating system depends on the number, capacity and rank counts of the DIMMs installed.

Internal storage

The ST550 supports 2.5-inch hot-swap, 3.5-inch hot-swap, and 3.5-inch simple-swap drives in a variety of drive bay configurations.

In this section:

Drive bays and backplanes

The server supports up to 20 drive bays: It can support up to 16x 2.5-inch drives or 8x 3.5-inch drives, plus an additional 4x 2.5-inch drive bays installed in the space occupied by the two 5.25-inch media bays. Hot-swap (HS) drive configurations support SAS & SATA drives, and with an AnyBay backplane, can support up to four NVMe drives. Simple-swap (SS) drive configurations support SATA drives only. The server also supports one or two M.2 drives, installed in an M.2 adapter. The dual-M.2 adapter provides RAID 0 and 1 support.

The different drive bay configurations supported are shown in the following figure.

Internal drive bay configurations
Figure 5. Internal drive bay configurations

The following table lists all available drive configurations.

Table 13. Drive configurations
Configuration Backplane 5.25-inch media bays
2.5-inch hot-swap drive bay configurations
8x 2.5-inch SAS/SATA One 8x2.5-inch SAS/SATA Available
8x 2.5-inch SAS/SATA,
4 bays supporting NVMe
One 8x2.5-inch AnyBay Available
16x 2.5-inch SAS/SATA Two 8x2.5-inch SAS/SATA Available
16x 2.5-inch SAS/SATA,
4 bays supporting NVMe
One 8x2.5-inch SAS/SATA +
One 8x2.5-inch AnyBay
Available
20x 2.5-inch SAS/SATA Two 8x2.5-inch SAS/SATA +
4x2.5-inch Media Bay conversion
Converted to
2.5-inch drive bays
20x 2.5-inch SAS/SATA,
4 bays supporting NVMe
One 8x2.5-inch SAS/SATA +
One 8x2.5-inch AnyBay +
4x2.5-inch Media Bay conversion
Converted to
2.5-inch drive bays
3.5-inch and 3.5+2.5-inch hot-swap drive bay hybrid configurations
4x 3.5-inch SAS/SATA One 4x3.5-inch SAS/SATA Available
8x 3.5-inch SAS/SATA One 8x3.5-inch SAS/SATA Available
8x 3.5-inch SAS/SATA +
4x 2.5-inch SAS/SATA
One 8x3.5-inch SAS/SATA +
4x2.5-inch Media Bay conversion
Converted to
2.5-inch drive bays
3.5-inch simple-swap drive bay configurations
4x 3.5-inch SATA One Simple-swap bracket plate Available
8x 3.5-inch SATA Two Simple-swap bracket plates Available

The drive backplanes used with these configurations are listed in the following table.

Table 14. Drive backplanes
Part number Feature Description Purpose
None* AVRN ThinkSystem ST550 2.5" SATA/SAS 8-Bay Backplane 2.5-inch SAS/SATA
None* AUR5 ThinkSystem 2U/Twr 2.5" AnyBay 8-Bay Backplane 2.5-inch AnyBay
None* AVRQ ThinkSystem ST550 4x3.5" Backplane 3.5-inch SAS/SATA
None* AVRM ThinkSystem ST550 2.5" SATA/SAS 4-Bay Backplane Media bay conversion
None* AVRY ThinkSystem ST550 3.5" SATA 4-Bay Simple Swap Backplate Simple-swap drives

* Backplanes are configure-to-order only, however upgrade kits are available that include backplanes, as described in the Field upgrades section below.

Adapters and cabling

This section describes the adapter and cabling requirements for each drive bay configuration.

Notes:

  • For configurations with 16x 2.5-inch drive bays (i.e., two backplanes), you can select either one 16-port SAS/SATA adapter or two 8-port SAS/SATA adapters
  • For configurations with 20x 2.5-inch drive bays, a single 24-port SAS/SATA adapter is used.
  • For the use of AnyBay drive bays, a NVMe Switch adapter is used to provide the NVMe ports. The adapter is installed in slot 2 (which connects to processor 1).

The drive bay configurations are shown in the the subsections below. Where there are different adapter and cabling options, they are shown by the letters A, B, C, D. These configuration numbers are also referenced later in the Field upgrades section.

  1. 8x 2.5-inch hot-swap drive bays, all SAS/SATA
  2. 8x 2.5-inch hot-swap drive bays, where 4 of the bays are AnyBay
  3. 16x 2.5-inch hot-swap drive bays, all SAS/SATA
  4. 16x 2.5-inch hot-swap drive bays, where 4 of the bays are AnyBay
  5. 20x 2.5-inch hot-swap drive bays, all SAS/SATA
  6. 20x 2.5-inch hot-swap drive bays, where 4 of the bays are AnyBay
  7. 4x 3.5-inch drive bays, all SAS/SATA
  8. 8x 3.5-inch hot-swap hot-swap drive bays, all SAS/SATA
  9. 8x 3.5-inch + 4x 2.5-in hot-swap drive bays, all SAS/SATA
  10. 4x 3.5-inch simple-swap drive bays, SATA only
  11. 8x 3.5-inch simple-swap drive bays, SATA only

Tip: The adapters are described in detail in the Controllers for internal storage section.

1. 8x 2.5-inch hot-swap drive bays, all SAS/SATA

In this drive bay configuration, all eight 2.5-inch hot-swap drives are connected to one 8-port SAS/SATA RAID adapter or HBA using two backplane cables, as shown in the following figure.

Adapter and cabling for 8x 2.5-inch drive bays, all SAS/SATA
Figure 6. Adapter and cabling for 8x 2.5-inch drive bays, all SAS/SATA

2. 8x 2.5-inch hot-swap drive bays, where four of the bays are AnyBay

In 8x 2.5-inch drive-bay configurations where four of those bays are AnyBay drive bays, an 8-port SAS/SATA RAID adapter or HBA is needed plus an NVMe Switch Adapter to provide the four needed NVMe ports.

In this configuration you can have either up to eight SAS or SATA drives, or you can have up to four NVMe drives in the four AnyBay drive bays along with four SAS or SATA drives in the other bays.

Adapter and cabling for 8x 2.5-in drive bays, where 4 of the bays are AnyBay
Figure 7. Adapter and cabling for 8x 2.5-inch drive bays, where 4 of the bays are AnyBay

3. 16x 2.5-inch hot-swap drive bays, all SAS/SATA

In 16-bay configurations where all 16 2.5-inch drive bays are SAS/SATA drives, you can use either two 8-port SAS/SATA RAID adapters or HBAs or one 16-port SAS/SATA RAID adapter or HBA. These choices are shown in the following figure.

16x 2.5-in drive bays, all SAS/SATA
Figure 8. Adapter and cabling for 16 drive bays, all SAS/SATA

4. 16x 2.5-inch hot-swap drive bays, where four of the bays are AnyBay

In 16-drive configurations where four of the 2.5-inch bays are AnyBay drive bays, a 16-port SAS/SATA RAID adapter or HBA is needed plus an NVMe Switch Adapter to provide the four needed NVMe ports. The configurations are shown in the following figure.

Adapter and cabling for 16 drive bays, where 4 of the bays are AnyBay
Figure 9. Adapter and cabling for 16 drive bays, where 4 of the bays are AnyBay

5. 20x 2.5-inch hot-swap drive bays, all SAS/SATA

In a 20-drive configuration, where all drives are SAS or SATA, all connectivity is provided by a single 24-port SAS/SATA RAID adapter. The top four drive bays are in place of the two 5.25" media bays.   Connectivity is shown in the following figure.

20x 2.5-in drive bays, all SAS/SATA
Figure 10. Adapter and cabling for 20 drive bays, all SAS/SATA

6. 20x 2.5-inch hot-swap drive bays, where four of the bays are AnyBay

In this 20-drive configuration, all drives can be SAS or SATA drives, or four can be NVMe drives. SAS/SATA connectivity is provided by a single 24-port SAS/SATA RAID adapter. NVMe connectivity is provided by the NVMe Switch Adapter. The top four drive bays are in place of the two 5.25" media bays. Connectivity is shown in the following figure.

Adapter and cabling for 20 drive bays, where 4 of the bays are AnyBay
Figure 11. Adapter and cabling for 20 drive bays, where 4 of the bays are AnyBay

7. 4x 3.5-inch hot-swap drive bays, all SAS/SATA

In this drive bay configuration, four 3.5-inch hot-swap drives are connected to one 8-port SAS/SATA RAID adapter or HBA using a single backplane cable, as shown in the following figure.

Adapter and cabling for 4x 3.5-inch drive bays, all SAS/SATA
Figure 12. Adapter and cabling for 4x 3.5-inch drive bays, all SAS/SATA

8. 8x 3.5-inch hot-swap drive bays, all SAS/SATA

In this drive bay configuration, eight 3.5-inch hot-swap drives are connected to one 8-port SAS/SATA RAID adapter or HBA using two backplane cables, as shown in the following figure.

Adapter and cabling for 8x 3.5-inch drive bays, all SAS/SATA
Figure 13. Adapter and cabling for 8x 3.5-inch drive bays, all SAS/SATA

9. 8x 3.5-inch + 4x 2.5-inch hot-swap drive bays, all SAS/SATA

In this combination drive configuration, eight 3.5-in drives and four 2.5-inch drives are supported. The top four drive bays are in place of the two 5.25" media bays. All connectivity can be provided by a single 16-port adapter or two 8-port adapters. Connectivity options are shown in the following figure.

Adapter and cabling for 8x 3.5-in + 4x 2.5-in drive bays, all SAS/SATA
Figure 14. Adapter and cabling for 8x 3.5-inch + 4x 2.5-inch drive bays, all SAS/SATA

10. 4x 3.5-inch simple-swap drive bays, SATA only

In this configuration, the server supports four 3.5-inch simple-swap (SS) drive bays, which support only SATA HDDs and SSDs. The drives connect to a single simple-swap bracket plate, which in turn plugs into a mini-SAS HD connector on the system board.

Adapter and cabling for 4x 3.5-in simple-swap drive bays, SATA only
Figure 15. Adapter and cabling for 4x 3.5-inch simple-swap drive bays; SATA only

11. 8x 3.5-inch simple-swap drive bays, SATA only

In this configuration, the server supports eight 3.5-inch simple-swap drives bays, which support only SATA HDDs and SSDs. The drives connect to two simple-swap bracket plates, which in turn each plug into a mini-SAS HD connector on the system board.

8x 3.5-in simple-swap drive bays, SATA only
Figure 16. Adapter and cabling for 8x 3.5-inch simple-swap drive bays; SATA only

Field upgrades

The following table shows the backplane kits you can use after the initial purchase to upgrade the server to add additional drive bays.

Table 15. Drive backplane upgrades
Part number Feature Description Purpose
7XH7A05906 AVRN ThinkSystem ST550 2.5" SATA/SAS 8-Bay Backplane Add 8x 2.5-inch SAS/SATA
7XH7A05907 B0M8 ThinkSystem ST550 2.5" Anybay 8-Bay Backplane Kit Add 8x 2.5-inch AnyBay
7XH7A05908 AVRM ThinkSystem ST550 2.5" SATA/SAS 4-Bay Backplane Add 4x 2.5-inch to media bay
(replace existing 5.25" bays)
7XH7A05905 AVRQ ThinkSystem ST550 3.5" SATA/SAS 4-Bay Backplane Add 4x 3.5-inch HS SAS/SATA
7XH7A05904 AVRY ThinkSystem ST550 3.5" SATA 4-Bay Simple Swap Backplate Add 4x 3.5-inch simple-swap

Each kit contains the backplane and the necessary cables (including PCIe cables for the AnyBay backplane). The 2.5" SATA/SAS 4-Bay Backplane Kit also includes the necessary 4x 2.5-inch drive-bay cage. 

In addition to the backplane kits, you will need a RAID adapter or HBA, and if you are adding an AnyBay backplane, you'll also need an NVMe Switch adapter. The adapters are described in the Controllers for internal storage section.

M.2 drives

The server supports one or two M.2 form-factor SATA drives for use as an operating system boot solution. With two M.2 drives configured, the drives are configured by default as a RAID-1 mirrored pair for redundancy.

The M.2 drives install into an M.2 adapter which in turn is installed in a dedicated slot on the system board. See the internal view of the server in the Components and connectors section for the location of the M.2 slot.

There are two M.2 adapters supported, as listed in the following table.

Table 16. M.2 components
Part
number
Feature
code
Description Maximum
supported
7Y37A01092 AUMU ThinkSystem M.2 Enablement Kit
(contains the Single M.2 Boot Adapter; supports 1 drive)
1
7Y37A01093 AUMV ThinkSystem M.2 with Mirroring Enablement Kit
(contains the Dual M.2 Boot Adapter, supports 1 or 2 drives)
1

Supported drives are listed in the Internal drive options section.

For details about M.2 components, see the ThinkSystem M.2 Drives and M.2 Adapters product guide:
https://lenovopress.com/lp0769-thinksystem-m2-drives-adapters

SED encryption key management with ISKLM

The server supports self-encrypting drives (SEDs) and FIPS 140-2 drives as described in the Internal drive options section. To effectively manage a large deployment of these drives in Lenovo servers, IBM Security Key Lifecycle Manager (SKLM) offers a centralized key management solution. A Lenovo Feature on Demand (FoD) upgrade is used to enable this SKLM support in the management processor of the server.

The following table lists the part numbers and feature codes for the upgrades.

Table 17. FoD upgrades for SKLM support
Part number Feature code Description
Security Key Lifecycle Manager - FoD (United States, Canada, Asia Pacific, and Japan)
00D9998 A5U1 SKLM for System x/ThinkSystem w/SEDs - FoD per Install with 1 year S&S
00D9999 AS6C SKLM for System x/ThinkSystem w/SEDs - FoD per Install with 3 year S&S
Security Key Lifecycle Manager - FoD (Latin America, Europe, Middle East, and Africa)
00FP648 A5U1 SKLM for System x/ThinkSystem w/SEDs - FoD per Install with 1 year S&S
00FP649 AS6C SKLM for System x/ThinkSystem w/SEDs - FoD per Install with 3 year S&S

Controllers for internal storage

The ST550 with hot-swap drives supports internal SAS and SATA drives with the addition of a RAID adapter or HBA. For NVMe support, the server supports the use of an NVMe Switch Adapter installed in a PCIe slot.

For simple-swap drive support, the ST550 uses two onboard 6Gb SATA ports to connect the four or eight simple-swap drives. These ports enable Intel RSTe for RAID functionality.

Virtualization support: The SATA ports can be used with virtualization hypervisors, including VMware ESXi, Linux KVM, Xen, and Microsoft Hyper-V, however support is limited to AHCI (non-RAID) mode. RSTe mode is not supported with virtualization hypervisors.

The following table lists the adapters used for the internal disk storage of the ST550 server.

Table 18. Controllers for internal storage - hot-swap drive support
Part number Feature code Description Number
of ports
Maximum
supported
SAS/SATA HBA
7Y37A01088 AUNL ThinkSystem 430-8i SAS/SATA 12Gb HBA 8 2
7Y37A01089 AUNM ThinkSystem 430-16i SAS/SATA 12Gb HBA 16 1
RAID adapters
7Y37A01082 AUNG ThinkSystem RAID 530-8i PCIe 12Gb Adapter 8 2
7Y37A01083* AUNH* ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter 8 2
7Y37A01084 AUNJ ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter 8 2
7Y37A01085 AUNK ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter 16 1
7Y37A01086 AUV1 ThinkSystem RAID 930-24i 4GB Flash PCIe 12Gb Adapter 24 1
NVMe adapter
7Y37A01081 AUV2 ThinkSystem 1610-4P NVMe Switch Adapter 4 1

* The RAID 730-8i adapter is available in China only

The following two tables compare the functions of the storage adapters and the onboard SATA.

Table 19. Comparison of internal storage controllers - RAID controllers
Feature RAID 530-8i RAID 730-8i* RAID 930-8i RAID 930-16i RAID 930-24i
Adapter type RAID controller RAID controller RAID controller RAID controller RAID controller
Part number 7Y37A01082 7Y37A01083 7Y37A01084 7Y37A01085 7Y37A01086
Form factor PCIe HHHL PCIe low profile PCIe HHHL PCIe HHHL PCIe HHHL
Controller chip LSI SAS3408 LSI SAS3108 LSI SAS3508 LSI SAS3516 LSI SAS3508 + LSI SAS35x36R
Broadcom equivalent MegaRAID 9440-8i MegaRAID 9361-8i MegaRAID 9460-8i MegaRAID 9460-16i MegaRAID 9460-24i
Host interface PCIe 3.0x8 PCIe 3.0x8 PCIe 3.0x8 PCIe 3.0x8 PCIe 3.0x8
Port interface 12 Gb SAS 12 Gb SAS 12 Gb SAS 12 Gb SAS 12 Gb SAS
Number of ports 8 8 8 16 24
Port connectors 2x Mini-SAS HD x4 (SFF-8643) 2x Mini-SAS HD x4 (SFF-8643) 2x Mini-SAS HD x4 (SFF-8643) 4x Mini-SAS HD x4 (SFF-8643) 6x Mini-SAS HD x4 (SFF-8643)
Drive interface SAS, SATA SAS, SATA SAS, SATA SAS, SATA SAS, SATA
Drive type HDD, SED, SSD HDD, SSD HDD, SED, SSD HDD, SED, SSD HDD, SED, SSD
Hot-swap drives Yes Yes Yes Yes Yes
Max devices 8 8 8 16 24**
RAID levels 0, 1, 10, 5, 50 0, 1, 10, 5, 50 0, 1, 10, 5, 50, 6, 60 0, 1, 10, 5, 50, 6, 60 0, 1, 10, 5, 50, 6, 60
JBOD mode Yes Yes Yes Yes Yes
Cache None 1GB (Standard) 2GB (Standard) 4GB (Standard) 4GB (Standard)
CacheVault cache protection No No Yes (Flash) Yes (Flash) Yes (Flash)
Performance Accelerator (FastPath) Yes No Yes Yes Yes
SSD Caching (CacheCade Pro 2.0) No No No No No
SED support† Yes No Yes Yes Yes

* The RAID 730-8i adapter is available in China only
† SED support by RAID controllers is provided using the built-in MegaRAID SafeStore functionality of the adapter.
** With the ST550, the RAID 930-24i supports up to 20 drives.

Table 20. Comparison of internal storage controllers - HBAs and NVMe Switch Adapter
Feature Intel RSTe 430-8i 430-16i 1610-4P NVMe
Adapter type Software RAID HBA HBA NVMe switch
Part number None 7Y37A01088 7Y37A01089 7Y37A01081
Form factor Onboard PCIe low profile PCIe low profile PCIe HHHL
Controller chip Intel PCH (RSTe) LSI SAS3408 LSI SAS3416 Broadcom PEX9733
Broadcom equivalent Not applicable HBA 9400-8i HBA 9400-16i P310W-4P
Host interface Not applicable PCIe 3.0 x8 PCIe 3.0 x8 PCIe 3.0 x8
Port interface 6 Gb SATA 12 Gb SAS 12 Gb SAS PCIe
Number of ports Varies 8 16 4
Port connectors Onboard 2x Mini-SAS HD x4 (SFF-8643) 4x Mini-SAS HD x4 (SFF-8643) 4x Mini-SAS HD x4 (SFF-8643)
Drive interface SATA SAS, SATA SAS, SATA PCIe NVMe
Drive type HDD, SSD HDD, SSD, SED** HDD, SSD, SED** SSD
Hot-swap drives No Yes Yes No
Max devices Varies 8 16 4
RAID levels 0, 1, 10, 5 No RAID No RAID No RAID
JBOD mode Yes Yes Yes Yes
Cache None No No None
CacheVault cache protection No No No No
Performance Accelerator (FastPath) No No No No
SSD Caching (CacheCade Pro 2.0) No No No No
SED support No Yes** Yes** No

** SED support of the SAS HBAs is by using software on the server (SED commands are passed through the HBA to the drives).

Internal drive options

The following tables list the hard disk drive and solid-state drive options for the internal disk storage of the server.

Tip: The use of M.2 drives requires an additional adapter as described in the M.2 drives subsection.

Table 21. 2.5-inch hot-swap 12 Gb SAS HDDs
Part number Feature Description Maximum
supported
2.5-inch hot-swap HDDs - 12 Gb SAS 10K
7XB7A00024 AULY ThinkSystem 2.5" 300GB 10K SAS 12Gb Hot Swap 512n HDD 20
7XB7A00025 AULZ ThinkSystem 2.5" 600GB 10K SAS 12Gb Hot Swap 512n HDD 20
7XB7A00026 AUM0 ThinkSystem 2.5" 900GB 10K SAS 12Gb Hot Swap 512n HDD 20
7XB7A00027 AUM1 ThinkSystem 2.5" 1.2TB 10K SAS 12Gb Hot Swap 512n HDD 20
7XB7A00028 AUM2 ThinkSystem 2.5" 1.8TB 10K SAS 12Gb Hot Swap 512e HDD 20
7XB7A00069 B0YS ThinkSystem 2.5" 2.4TB 10K SAS 12Gb Hot Swap 512e HDD 20
2.5-inch hot-swap HDDs - 12 Gb SAS 15K
7XB7A00021 AULV ThinkSystem 2.5" 300GB 15K SAS 12Gb Hot Swap 512n HDD 20
7XB7A00022 AULW ThinkSystem 2.5" 600GB 15K SAS 12Gb Hot Swap 512n HDD 20
7XB7A00023 AULX ThinkSystem 2.5" 900GB 15K SAS 12Gb Hot Swap 512e HDD 20
2.5-inch hot-swap HDDs - 12 Gb NL SAS
7XB7A00034 AUM6 ThinkSystem 2.5" 1TB 7.2K SAS 12Gb Hot Swap 512n HDD 20
7XB7A00035 AUM7 ThinkSystem 2.5" 2TB 7.2K SAS 12Gb Hot Swap 512n HDD 20
2.5-inch hot-swap SED HDDs - 12 Gb SAS 10K
7XB7A00030 AUM4 ThinkSystem 2.5" 300GB 10K SAS 12Gb Hot Swap 512n HDD SED 20
7XB7A00031 AUM5 ThinkSystem 2.5" 600GB 10K SAS 12Gb Hot Swap 512n HDD SED 20
7XB7A00033 B0YX ThinkSystem 2.5" 1.2TB 10K SAS 12Gb Hot Swap 512n HDD SED 20
Table 22. 2.5-inch hot-swap 6 Gb SAS/SATA HDDs
Part number Feature Description Maximum
supported
2.5-inch hot-swap HDDs - 6 Gb NL SATA
7XB7A00036 AUUE ThinkSystem 2.5" 1TB 7.2K SATA 6Gb Hot Swap 512n HDD 20
7XB7A00037 AUUJ ThinkSystem 2.5" 2TB 7.2K SATA 6Gb Hot Swap 512e HDD 20
Table 23. 2.5-inch hot-swap 12 Gb SAS SSDs
Part number Feature Description Maximum
supported
2.5-inch hot-swap SSDs - 12 Gb SAS - Enterprise Capacity
7N47A00121 AUMK ThinkSystem 2.5" PM1633a 3.84TB Capacity SAS 12Gb Hot Swap SSD 20
7N47A00122 AUML ThinkSystem 2.5" PM1633a 7.68TB Capacity SAS 12Gb Hot Swap SSD 20
7N47A00123 B116 ThinkSystem 2.5" PM1633a 15.36TB Capacity SAS 12Gb Hot Swap SSD 20
2.5-inch hot-swap SSDs - 12 Gb SAS - Enterprise Mainstream (3-5 DWPD)
7N47A00117 AUMC ThinkSystem 2.5" PM1635a 400GB Mainstream SAS 12Gb Hot Swap SSD 20
7N47A00118 AUMD ThinkSystem 2.5" PM1635a 800GB Mainstream SAS 12Gb Hot Swap SSD 20
7N47A00119 AVRG ThinkSystem 2.5" PM1635a 1.6TB Mainstream SAS 12Gb Hot Swap SSD 20
Table 24. 2.5-inch hot-swap 6 Gb SAS/SATA SSDs
Part number Feature Description Maximum
supported
2.5-inch hot-swap SSDs - 6 Gb SATA - Enterprise Mainstream (3-5 DWPD)
7SD7A05765 B10W ThinkSystem 2.5" 5100 240GB Mainstream SATA 6Gb Hot Swap SSD 20
7SD7A05764 B10X ThinkSystem 2.5" 5100 480GB Mainstream SATA 6Gb Hot Swap SSD 20
7SD7A05763 B10Y ThinkSystem 2.5" 5100 960GB Mainstream SATA 6Gb Hot Swap SSD 20
7SD7A05762 B10Z ThinkSystem 2.5" 5100 1.92TB Mainstream SATA 6Gb Hot Swap SSD 20
7SD7A05761 B110 ThinkSystem 2.5" 5100 3.84TB Mainstream SATA 6Gb Hot Swap SSD 20
7SD7A05723 B0ZP ThinkSystem 2.5" Intel S4600 240GB Mainstream SATA 6Gb Hot Swap SSD 20
7SD7A05722 B0ZQ ThinkSystem 2.5" Intel S4600 480GB Mainstream SATA 6Gb Hot Swap SSD 20
7SD7A05721 B0ZR ThinkSystem 2.5" Intel S4600 960GB Mainstream SATA 6Gb Hot Swap SSD 20
7SD7A05720 B0ZS ThinkSystem 2.5" Intel S4600 1.92TB Mainstream SATA 6Gb Hot Swap SSD 20
2.5-inch hot-swap SSDs - 6 Gb SATA - Enterprise Entry (<3 DWPD)
7N47A00099 AUM8 ThinkSystem 2.5" Intel S3520 240GB Entry SATA 6Gb Hot Swap SSD 20
7N47A00100 AUUZ ThinkSystem 2.5" Intel S3520 480GB Entry SATA 6Gb Hot Swap SSD 20
7N47A00111 AUUQ ThinkSystem 2.5" PM863a 240GB Entry SATA 6Gb Hot Swap SSD 20
7N47A00112 AUM9 ThinkSystem 2.5" PM863a 480GB Entry SATA 6Gb Hot Swap SSD 20
7N47A00113 AVCZ ThinkSystem 2.5" PM863a 960GB Entry SATA 6Gb Hot Swap SSD 20
7N47A00114 AVRC ThinkSystem 2.5" PM863a 1.92TB Entry SATA 6Gb Hot Swap SSD 20
7SD7A05742 B0YY ThinkSystem 2.5" Intel S4500 240GB Entry SATA 6Gb Hot Swap SSD 20
7SD7A05741 B0YZ ThinkSystem 2.5" Intel S4500 480GB Entry SATA 6Gb Hot Swap SSD 20
7SD7A05740 B0Z0 ThinkSystem 2.5" Intel S4500 960GB Entry SATA 6Gb Hot Swap SSD 20
7SD7A05739 B0Z1 ThinkSystem 2.5" Intel S4500 1.92TB Entry SATA 6Gb Hot Swap SSD 20
7SD7A05738 B0Z2 ThinkSystem 2.5" Intel S4500 3.84TB Entry SATA 6Gb Hot Swap SSD 20
4XB7A08503 B10P ThinkSystem 2.5" 5100 960GB Entry SATA 6Gb Hot Swap SSD 20
4XB7A08502 B10N ThinkSystem 2.5" 5100 480GB Entry SATA 6Gb Hot Swap SSD 20
4XB7A08504 B10Q ThinkSystem 2.5" 5100 1.92TB Entry SATA 6Gb Hot Swap SSD 20
4XB7A08505 B10R ThinkSystem 2.5" 5100 3.84TB Entry SATA 6Gb Hot Swap SSD 20
Table 25. 2.5-inch U.2 NVMe SSDs
Part number Feature Description Maximum
supported
2.5-inch SSDs - NVMe - Enterprise Entry (<3 DWPD)
7N47A00984 AUV0 ThinkSystem U.2 PM963 1.92TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD 4
7N47A00985 AUUU ThinkSystem U.2 PM963 3.84TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD 4

Note: NVMe PCIe SSDs support informed hot removal and hot insertion, provided the operating system supports PCIe SSD hot-swap.

Table 26. 3.5-inch hot-swap 12 Gb SAS HDDs
Part number Feature Description Maximum
supported
3.5-inch hot-swap HDDs - 12 Gb SAS 15K
7XB7A00038 AUU2 ThinkSystem 3.5" 300GB 15K SAS 12Gb Hot Swap 512n HDD 8
7XB7A00039 AUU3 ThinkSystem 3.5" 600GB 15K SAS 12Gb Hot Swap 512n HDD 8
3.5-inch hot-swap HDDs - 12 Gb NL SAS
7XB7A00041 AUU4 ThinkSystem 3.5" 1TB 7.2K SAS 12Gb Hot Swap 512n HDD 8
7XB7A00042 AUU5 ThinkSystem 3.5" 2TB 7.2K SAS 12Gb Hot Swap 512n HDD 8
7XB7A00043 AUU6 ThinkSystem 3.5" 4TB 7.2K SAS 12Gb Hot Swap 512n HDD 8
7XB7A00044 AUU7 ThinkSystem 3.5" 6TB 7.2K SAS 12Gb Hot Swap 512e HDD 8
7XB7A00045 B0YR ThinkSystem 3.5" 8TB 7.2K SAS 12Gb Hot Swap 512e HDD 8
7XB7A00046 AUUG ThinkSystem 3.5" 10TB 7.2K SAS 12Gb Hot Swap 512e HDD 8
7XB7A00067 B117 ThinkSystem 3.5" 12TB 7.2K SAS 12Gb Hot Swap 512e HDD 8
Table 27. 3.5-inch hot-swap 6 Gb SAS/SATA HDDs
Part number Feature Description Maximum
supported
3.5-inch hot-swap HDDs - 6 Gb NL SATA
7XB7A00049 AUUF ThinkSystem 3.5" 1TB 7.2K SATA 6Gb Hot Swap 512n HDD 8
7XB7A00050 AUUD ThinkSystem 3.5" 2TB 7.2K SATA 6Gb Hot Swap 512n HDD 8
7XB7A00051 AUU8 ThinkSystem 3.5" 4TB 7.2K SATA 6Gb Hot Swap 512n HDD 8
7XB7A00053 AUU9 ThinkSystem 3.5" 8TB 7.2K SATA 6Gb Hot Swap 512e HDD 8
7XB7A00054 AUUB ThinkSystem 3.5" 10TB 7.2K SATA 6Gb Hot Swap 512e HDD 8
7XB7A00068 B118 ThinkSystem 3.5" 12TB 7.2K SATA 6Gb Hot Swap 512e HDD 8
Table 28. 3.5-inch hot-swap 6 Gb SAS/SATA SSDs
Part number Feature Description Maximum
supported
3.5-inch hot-swap SSDs - 6 Gb SATA - Enterprise Mainstream (3-5 DWPD)
7SD7A05718 B0ZT ThinkSystem 3.5" Intel S4600 240GB Mainstream SATA 6Gb Hot Swap SSD 8
7SD7A05717 B0ZU ThinkSystem 3.5" Intel S4600 480GB Mainstream SATA 6Gb Hot Swap SSD 8
7SD7A05716 B0ZV ThinkSystem 3.5" Intel S4600 960GB Mainstream SATA 6Gb Hot Swap SSD 8
7SD7A05715 B109 ThinkSystem 3.5" Intel S4600 1.92TB Mainstream SATA 6Gb Hot Swap SSD 8
7SD7A05760 B111 ThinkSystem 3.5" 5100 240GB Mainstream SATA 6Gb Hot Swap SSD 8
7SD7A05759 B112 ThinkSystem 3.5" 5100 480GB Mainstream SATA 6Gb Hot Swap SSD 8
7SD7A05758 B113 ThinkSystem 3.5" 5100 960GB Mainstream SATA 6Gb Hot Swap SSD 8
7SD7A05757 B114 ThinkSystem 3.5" 5100 1.92TB Mainstream SATA 6Gb Hot Swap SSD 8
7SD7A05756 B115 ThinkSystem 3.5" 5100 3.84TB Mainstream SATA 6Gb Hot Swap SSD 8
3.5-inch hot-swap SSDs - 6 Gb SATA - Enterprise Entry (<3 DWPD)
7N47A00115 AUUS ThinkSystem 3.5" PM863a 240GB Entry SATA 6Gb Hot Swap SSD 8
7N47A00116 AUUN ThinkSystem 3.5" PM863a 480GB Entry SATA 6Gb Hot Swap SSD 8
7N47A00106 AUUT ThinkSystem 3.5" Intel S3520 480GB Entry SATA 6Gb Hot Swap SSD 8
7N47A00105 AUUW ThinkSystem 3.5" Intel S3520 240GB Entry SATA 6Gb Hot Swap SSD 8
7SD7A05737 B0Z3 ThinkSystem 3.5" Intel S4500 240GB Entry SATA 6Gb Hot Swap SSD 8
7SD7A05736 B0Z4 ThinkSystem 3.5" Intel S4500 480GB Entry SATA 6Gb Hot Swap SSD 8
7SD7A05735 B0Z5 ThinkSystem 3.5" Intel S4500 960GB Entry SATA 6Gb Hot Swap SSD 8
7SD7A05734 B0Z6 ThinkSystem 3.5" Intel S4500 1.92TB Entry SATA 6Gb Hot Swap SSD 8
7SD7A05733 B0Z7 ThinkSystem 3.5" Intel S4500 3.84TB Entry SATA 6Gb Hot Swap SSD 8
4XB7A08506 B10S ThinkSystem 3.5" 5100 480GB Entry SATA 6Gb Hot Swap SSD 8
4XB7A08507 B10T ThinkSystem 3.5" 5100 960GB Entry SATA 6Gb Hot Swap SSD 8
4XB7A08508 B10U ThinkSystem 3.5" 5100 1.92TB Entry SATA 6Gb Hot Swap SSD 8
4XB7A08509 B10V ThinkSystem 3.5" 5100 3.84TB Entry SATA 6Gb Hot Swap SSD 8
Table 29. 3.5-inch simple-swap 6 Gb SAS/SATA HDDs
Part number Feature Description Maximum
supported
3.5-inch simple-swap HDDs - 6 Gb NL SATA
7XB7A00055 AUZS ThinkSystem 1TB 7.2K 6Gbps SATA 3.5" Simple Swap 512n HDD 8
7XB7A00056 AUZT ThinkSystem 2TB 7.2K 6Gbps SATA 3.5" Simple Swap 512n HDD 8
7XB7A00057 AUZU ThinkSystem 4TB 7.2K 6Gbps SATA 3.5" Simple Swap 512n HDD 8
7XB7A00052 AXC7 ThinkSystem 6TB 7.2K 6Gbps SATA 3.5" Simple Swap 512e HDD 8
7XB7A00058 AUUA ThinkSystem 3.5" 6TB 7.2K SATA 6Gb Non-Hot Swap 512e HDD 8
7XB7A00059 AXC6 ThinkSystem 8TB 7.2K 6Gbps SATA 3.5" Simple Swap 512e HDD 8
7XB7A00060 AXC8 ThinkSystem 10TB 7.2K Gbps SATA 3.5" Simple Swap 512e HDD 8
Table 30. M.2 drives
Part number Feature Description Maximum
supported
M.2 SSDs - 6 Gb SATA - Enterprise Entry (<3 DWPD)
7N47A00129 AUUL ThinkSystem M.2 CV1 32GB SATA 6Gbps Non-Hot-Swap SSD 2
7N47A00130 AUUV ThinkSystem M.2 CV3 128GB SATA 6Gbps Non-Hot-Swap SSD 2
7SD7A05703 B11V ThinkSystem M.2 5100 480GB SATA 6Gbps Non-Hot-Swap SSD 2

Internal backup units

The server supports the internal backup unit options that are listed in the following table.

Table 31. Internal backup units
Part number Feature code Description Maximum supported
Drives
7T27A01502 AVF2 ThinkSystem Internal Half High LTO Gen6 SAS Tape Drive 1
7T27A01503 AVF5 ThinkSystem Internal Half High LTO Gen7 SAS Tape Drive 1
7T27A01501 AVF6 ThinkSystem Internal RDX USB 3.0 Dock 1
LTO Media
7TP7A01604 AVF4 ThinkSystem LTO Gen6 2.5TB Tape Not applicable
7TP7A01606 AVF7 ThinkSystem LTO Gen7 6TB Tape Not applicable
RDX Media
7TP7A01601 AVF8 ThinkSystem RDX 500GB Cartridge Not applicable
7TP7A01602 AVF1 ThinkSystem RDX 1TB Cartridge Not applicable
7TP7A01603 AVF0 ThinkSystem RDX 2TB Cartridge Not applicable
7TP7A04318 AXD1 ThinkSystem RDX 4TB Cartridge Not applicable

The RDX drive is attached via the USB 3.0 port on the system board.

The use of an LTO tape drive requires a SAS HBA, either the 430-8i or 430-16i SAS/SATA 12Gb HBA.

For more information about RDX drive and LTO tape drives, see the Backup Units page on the Lenovo Press site: https://lenovopress.com/servers/options/backup

Optical drives

The ST550 supports the optical drive options listed in the following table.

Table 32. Optical drives
Part number Feature code Description Maximum
supported
Internal optical drives
7XA7A01204 AVEZ ThinkSystem Half High SATA DVD-ROM Optical Disk Drive 2
7XA7A01202 AVEY ThinkSystem Half High SATA DVD-RW Optical Disk Drive 2
External optical drives
7XA7A05926 AVV8 ThinkSystem External USB DVD RW Optical Disk Drive 2

The internal optical drives in the table can be installed in any open 5.25-inch drive bay.

The Half High SATA DVD-ROM drive supports the following media and speeds for reading:

  • CD-ROM 48X
  • CD-DA (DAE) 48X
  • CD-R 48X
  • CD-RW 40X
  • DVD-ROM (single layer) 16X
  • DVD-ROM (dual layer) 12X
  • DVD-R (4.7 GB) 16X
  • DVD-R DL 8X
  • DVD+R 16X
  • DVD+R DL 8X
  • DVD-RW (4.7 GB) 8X
  • DVD+RW 8X
  • DVD-RAM (4.7/9.4 GB) 5X

The Half High SATA DVD-RW drive supports the same media and speeds for reading as HH DVD-ROM. In addition, this drive supports the following media and speeds for writing:

  • CD-R 24X
  • CD-RW 4X
  • High Speed CD-RW 10X
  • Ultra Speed CD-RW 16X
  • DVD-R 8X
  • DVD-R DL 8X
  • DVD+R 8X
  • DVD+R DL 8X
  • DVD-RW 6X
  • DVD+RW 8X
  • DVD-RAM 5X

The ThinkSystem External USB DVD RW Optical Disk Drive is based on the Lenovo Slim DVD Burner DB65 drive and has the following specifications:

  • Read:
    • CD-ROM 24X
    • CD-DA (DAE) 24X
    • CD-R 24X
    • CD-RW 24X
    • DVD-ROM (single layer) 8X
    • DVD-ROM (dual layer) 8X
    • DVD-R (4.7 GB) 8X
    • DVD-R DL 8X
    • DVD+R 8X
    • DVD+R DL 8X
    • DVD-RW (4.7 GB) 8X
    • DVD+RW 8X
    • DVD-RAM (4.7/9.4 GB) 6X
  • Write:
    • CD-R 10X (CLV), 24X (PCAV)
    • CD-RW 4X
    • High Speed CD-RW 10X
    • Ultra Speed CD-RW 24X
    • DVD-R 8X
    • DVD-R DL 6X
    • DVD+R 8X
    • DVD+R DL 6X
    • DVD-RW 6X
    • DVD+RW 8X
    • DVD-RAM 5X

I/O expansion options

The ST550 server supports up to six PCIe 3.0 slots: Four slots (1, 2, 3 and 6) are supported when only one CPU is installed. Slots 4 and 5 require the second processor. The slot lane widths, available power, and supported adapter height and length are as follows:

  • Slot 1: PCIe 3.0 x8 (25W); full-height, half-length
  • Slot 2: PCIe 3.0 x16 (75W); full-height, half-length
  • Slot 3: PCIe 3.0 x16 (75W); full-height, full-length
  • Slot 4: PCIe 3.0 x16 (x8 wired) (25W); full-height, full-length (requires second processor)
  • Slot 5: PCIe 3.0 x16 (75W); full-height, full-length (requires second processor)
  • Slot 6: PCIe 3.0 x8 (x4 wired) (25W); full-height, full-length

Slots 3 and 5 support double-wide GPUs. When double-wide adapters are used slots 4 and 6 cannot be used.

The following figure shows the locations of the PCIe slots.

ThinkSystem ST550 PCIe slots
Figure 17. ThinkSystem ST550 PCIe slots

Above the PCIe slots is a space for a COM Port Bracket which is used for making an external serial port available at the rear of the server. The following table lists the ordering information.

Table 33. ThinkSystem ST550 COM Port Upgrade Kit ordering information
Part
number
Feature
code
Description Maximum
Supported
7Z17A02577 AUSL ThinkSystem ST550 COM Port Upgrade Kit 1

Network adapters

The ST550 has two onboard Gigabit Ethernet ports, connected to the integrated Intel Ethernet Connection X722 controller. 

Note: The onboard Gigabit ports do not support 10 Mbps or 100 Mbps Ethernet connections.

The following table lists other supported network adapters. The maximum supported column indicates which slots each adapter is supported in. For slot locations see the I/O expansion options section.

Table 34. Network adapters
Part
number
Feature
code
Description Slots
supported
Maximum
supported
Gigabit Ethernet
7ZT7A00482 AUZX ThinkSystem NetXtreme PCIe 1Gb 2-Port RJ45 Ethernet Adapter By Broadcom All slots 6
7ZT7A00484 AUZV ThinkSystem NetXtreme PCIe 1Gb 4-Port RJ45 Ethernet Adapter By Broadcom All slots 6
7ZT7A00533 AUZZ ThinkSystem I350-F1 PCIe 1Gb 1-Port SFP Ethernet Adapter By Intel All slots 6
7ZT7A00534 AUZY ThinkSystem I350-T2 PCIe 1Gb 2-Port RJ45 Ethernet Adapter By Intel All slots 6
7ZT7A00535 AUZW ThinkSystem I350-T4 PCIe 1Gb 4-Port RJ45 Ethernet Adapter By Intel All slots 6
10 Gb Ethernet
00MM850 ATRY Intel X550-T1 Single Port 10GBase-T Adapter All slots 6
00MM860 ATPX Intel X550-T2 Dual Port 10GBase-T Adapter All slots 6
7ZT7A00496 AUKP ThinkSystem Broadcom NX-E PCIe 10Gb 2-Port Base-T Ethernet Adapter All slots 6
7ZT7A00537 AUKX ThinkSystem X710-DA2 PCIe 10Gb 2-Port SFP+ Ethernet Adapter All slots 6*

* Requires SFP+ transceivers or DAC cables that must be purchased separately. See the following table.

For more information, see the list of Lenovo Press Product Guides in the Ethernet adapters category:
https://lenovopress.com/servers/options/ethernet

The following table lists the supported 10 Gb Ethernet SFP+ optical transceivers and DAC cables. For multi-port adapters, all adapter ports must have the same type of transceiver or DAC cable selected.

Table 35. Supported optical transceivers and DAC cables - 10 Gb Ethernet
Part number Feature code Description
10 GbE SFP+ LR transceivers (for SFP+ adapters)
00FE331 B0RJ Lenovo 10GBASE-LR SFP+ Transceiver
90Y9412 A1PM Lenovo 10Gb/s LR SFP+ XCVR
10 GbE SFP+ SR transceivers (for SFP+ adapters)
46C3447 5053 Lenovo 10GBASE-SR SFP+ Transceiver
49Y4216 0069 Brocade 10Gb SFP+ SR Optical Transceiver
49Y4218 0064 QLogic 10Gb SFP+ SR Optical Transceiver
10 GbE SFP+ DAC cables (for SFP+ adapters)
00D6288 A3RG Lenovo 0.5m Passive SFP+ DAC Cable
90Y9427 A1PH Lenovo 1m Passive SFP+ DAC Cable
00AY764 A51N Lenovo 1.5m Passive SFP+ DAC Cable
00AY765 A51P Lenovo 2m Passive SFP+ DAC Cable
90Y9430 A1PJ Lenovo 3m Passive SFP+ DAC Cable
90Y9433 A1PK Lenovo 5m Passive SFP+ DAC Cable
00D6151 A3RH Lenovo 7m Passive SFP+ DAC Cable

SAS adapters for external storage

The following table lists the SAS HBAs and RAID adapters suitable for connectivity to external storage.

Table 36. Supported SAS HBAs and RAID adapters
Part
number
Feature
code
Description Slots
supported
Maximum
supported
12 Gb SAS HBA
7Y37A01090 AUNR ThinkSystem 430-8e SAS/SATA 12Gb HBA All slots 6
12 Gb RAID Adapter
7Y37A01087 AUNQ ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter All slots 4*

* Limited by the number of supercap mounts in the server

The following table summarizes the features of supported adapters.

Table 37. Comparison of features
Feature 430-8e RAID 930-8e
Adapter type HBA External RAID
Part number 7Y37A01090 7Y37A01087
Controller chip LSI SAS3408 LSI SAS3508
Broadcom equivalent HBA 9400-8e MegaRAID 9480-8e
Host interface PCIe 3.0x8 PCIe 3.0x8
Port interface 12 Gb SAS 12 Gb SAS
Number of ports 8 8
Port connectors 2x Mini-SAS HD SFF8644 2x Mini-SAS HD SFF8644
Drive interface SAS/SATA SAS,SATA
Drive type HDD/SSD/SED* HDD,SED,SSD
Hot-swap drives Yes Yes
Maximum devices 512 (planned: 1024) 64 (planned: 216)
RAID levels None 0/1/10/5/50/6/60
JBOD mode Yes Yes
Cache None 4GB (Standard)
CacheVault cache protection None Yes (Flash)
Performance Accelerator (FastPath) No Yes
SSD Caching (CacheCade Pro 2.0) No No
SED support* Yes* Yes

* SED (self-encrypting drive) support of the SAS HBA is by using software on the server (SED commands are passed through the HBA to the drives).

Fibre Channel host bus adapters

The following table lists the Fibre Channel HBAs supported by the server.

Table 38. Fibre Channel adapters
Part
number
Feature
code
Description Slots
supported
Maximum
supported
16 Gb Fibre Channel
01CV840 ATZV Emulex 16Gb Gen6 FC Dual-port HBA All slots 6
01CV830 ATZU Emulex 16Gb Gen6 FC Single-port HBA All slots 6
01CV760 ATZC QLogic 16Gb Enhanced Gen5 FC Dual-port HBA All slots 6
01CV750 ATZB QLogic 16Gb Enhanced Gen5 FC Single-port HBA All slots 6

For more information, see the list of Lenovo Press Product Guides in the Host bus adapters category:
https://lenovopress.com/servers/options/hba

Flash Storage adapters

The server currently does not support Flash Storage adapters.

GPU adapters

The ST550 server supports the graphics processing units (GPUs) listed in the following table. Up to two GPUs are supported when two processors are installed in a server (or one GPU with only one processor).

Table 39.
Part
number
Feature
code
Description Slots
supported
Maximum
supported
7C57A02877 AUW6 ThinkSystem NVIDIA Quadro P2000 5GB PCIe Active GPU 3, 5 2
7C57A02895 AVRK ThinkSystem NVIDIA Quadro P6000 24GB PCIe Active GPU 3, 5* 2

* The P6000 is a double-width adapter: When installed in slot 3, slot 4 is no longer available. When installed in slot 5, slot 6 is no longer available.

The following other rules apply:

  • If two GPUs are installed, they must be identical
  • The first GPU is installed in slot 3; the second GPU is installed in slot 5 and requires the second processor to be installed.
  • The number of GPUs that can be installed depends on the type of power supply that is installed and the drive bay configuration selected. For more information, see the Power Supplies section.
  • Cooling requirements and limitations in fan redundancy exist for some configurations as described in the Fans and coolingsection
  • The use of a GPU requires that Fan 4 (rear fan) be installed.

Tip: NVIDIA Pxxxx GPUs do not have the 1TB system memory limit that previous NVIDIA adapters had

Fans and cooling

The server can operate in environments up to ASHRAE A4 (45°C and 90% humidity). Details and restrictions are described in the Physical and electrical specifications section.

The server supports up to four simple-swap fans, three in the front of the server, just behind the drive bays and one installed at the rear of the server. See the Inside view in the Components and connectors section for locations.

Use of these fans is as follows:

  • Single processor systems require 2 fans, installed in the area behind drive bays
  • The third fan installed behind the drive bays (part number is 7XH7A06781) is required if either:
    • The server has two processors
    • The server has four 2.5-inch hot-swap drives bays installed in place of the two 5.25-inch media bays converted
  • Fan 4 (the fan at the rear of the server) can be installed as an N+1 redundant fan if desired. The part number is 7XH7A05900.
  • If a GPU is installed, Fan 4 is required and is non-redundant in most configurations. The following table indicates the cooling restrictions that apply when supported GPUs are installed:
    • Whether or not Fan 4 is redundant
    • Limits to ambient temperatures
Table 40. Cooling restrictions with GPUs installed
GPU configuration NVIDIA P2000 selected NVIDIA P6000 selected
One GPU installed Fan 4 is redundant
System is limited to ASHRAE A2 (35°C)
Fan 4 is non-redundant
System is limited to ASHRAE A2 (35°C)
Two GPUs installed Fan 4 is non-redundant
System is limited to ASHRAE A2 (35°C)
Fan 4 is non-redundant
System is limited to 30°C ambient

The table below lists the fan upgrades.

Table 41. Fan upgrades
Part number Feature code Description
7XH7A06781 AVS3 ThinkSystem ST550 Front Mid Fan Module for 4x2.5" ODD conversion
7XH7A05900 AVS4 ThinkSystem ST550 Rear Fan Module

Power supplies

The server supports either a single fixed power supply or one or two hot-swap power supplies. When two hot-swap power supplies are installed, they form a redundant pair. The following table lists the supported power supplies.

Table 42. Power supply options
Part number Feature
code
Description Maximum
supported
110V AC 220V AC 240V DC
China only
None* AVS1 450W (230V/115V) Gold AC Fixed (Cabled) Power Supply 1 Yes Yes No
7N67A00882 AWFT 550W (230V/115V) Platinum Hot-Swap Power Supply 2 Yes Yes Yes
7N67A00883 AWFS 750W (230/115V) Platinum Hot-Swap Power Supply 2 Yes Yes Yes
7N67A00884 AWFR 750W (230V) Titanium Hot-Swap Power Supply 2 No Yes Yes
7N67A00885 AWFQ 1100W (230V/115V) Platinum Hot-Swap Power Supply 2 Yes Yes Yes

* Configure-to-order only

550W, 750W and 1100W Platinum power supplies are auto-sensing and support both 110V AC (100-127V 50/60 Hz) and 220V AC (200-240V 50/60 Hz) power. The 750W Titanium power supply only supports 220V AC power. In China only, all four hot-swap power supplies also support 240V DC.

Power supply options do not include a line cord.

For server configurations, the inclusion of a power supply is model dependent. Configure-to-order models can be configured without a power cord if desired.

Configuration rules

The following table shows the power supplies supported with and without GPUs and with the various supported drive bay configurations.

For further power configuration of the server, use the Lenovo Capacity Planner, available at:
https://datacentersupport.lenovo.com/us/en/products/solutions-and-software/software/lenovo-capacity-planner/solutions/ht504651

Additional rules:

  • 550W, 750W, 1100W power supplies can be used all processors supported by the server
  • 450W power supply can only be used with processors that have a TDP of 85W or lower
  • 1100W power supply supports GPUs, however limitations on cooling fan redundancy exist for some configurations as described in the Fans and cooling section
Table 43. Power supply support for drive and GPU configurations
Power
supply
4x 3.5 SS 8x 3.5 HS 8x 2.5 HS 16x 2.5 HS 8x 2.5 HS
AnyBay
8x 3.5 +
4x 2.5 HS
16x 2.5 HS
AnyBay
20x 2.5 HS
AnyBay
20x 2.5 HS
Without any GPUs
450W Y* Y* Y* N N N N N N
550W Y Y Y N N N N N N
750W Y Y Y Y Y Y Y Y Y
1100W Y Y Y Y Y Y Y Y Y
With 1 or 2 GPUs**
450W N N N N N N N N N
550W N N N N N N N N N
750W N N N N N N N N N
1100W Y Y Y Y Y Y Y Y Y

* Only with processors that have a TDP of 85W or lower
** See the Fans and cooling section for cooling restrictions with GPUs

Power cords

Country-specific line cords and rack power cables can be ordered as listed in the following table.

Table 44. Power cords
Part number Feature code Description
Rack cables
00Y3043 A4VP 1.0m, 10A/100-250V, C13 to C14 Jumper Cord
39Y7937 6201 1.5m, 10A/100-250V, C13 to C14 Jumper Cord
4L67A08369 6570 2.0m, 13A/100-250V, C13 to C14 Jumper Cord
4L67A08366 6311 2.8m, 10A/100-250V, C13 to C14 Jumper Cord
4L67A08370 6400 2.8m, 13A/100-250V, C13 to C14 Jumper Cord
39Y7932 6263 4.3m, 10A/100-250V, C13 to C14 Jumper Cord
4L67A08371 6583 4.3m, 13A/100-250V, C13 to C14 Jumper Cord
Country-specific cables
39Y7930 6222 2.8m, 10A/250V, C13 to IRAM 2073 (Argentina) Line Cord
81Y2384 6492 4.3m, 10A/250V, C13 to IRAM 2073 (Argentina) Line Cord
39Y7924 6211 2.8m, 10A/250V, C13 to AS/NZS 3112 (Australia/NZ) Line Cord
81Y2383 6574 4.3m, 10A/250V, C13 to AS/NZS 3112 (Australia/NZ) Line Cord
69Y1988 6532 2.8m, 10A/250V, C13 to NBR 14136 (Brazil) Line Cord
81Y2387 6404 4.3m, 10A/250V, C13 to NBR 14136 (Brazil) Line Cord
39Y7928 6210 2.8m, 10A/220V, C13 to GB 2099.1 (China) Line Cord
81Y2378 6580 4.3m, 10A/250V, C13 to GB 2099.1 (China) Line Cord
39Y7918 6213 2.8m, 10A/250V, C13 to DK2-5a (Denmark) Line Cord
81Y2382 6575 4.3m, 10A/250V, C13 to DK2-5a (Denmark) Line Cord
39Y7917 6212 2.8m, 10A/250V, C13 to CEE 7/7 (Europe) Line Cord
81Y2376 6572 4.3m, 10A/250V, C13 to CEE 7/7 (Europe) Line Cord
39Y7927 6269 2.8m, 10A/250V, C13 to IS 6538 (India) Line Cord
81Y2386 6567 4.3m, 10A/250V, C13 to IS 6538 (India) Line Cord
39Y7920 6218 2.8m, 10A/250V, C13 to SI 32 (Israel) Line Cord
81Y2381 6579 4.3m, 10A/250V, C13 to SI 32 (Israel) Line Cord
39Y7921 6217 2.8m, 10A/250V, C13 to CEI 23-16 (Italy) Line Cord
81Y2380 6493 4.3m, 10A/250V, C13 to CEI 23-16 (Italy) Line Cord
4L67A08362 6495 4.3m, 12A/200V, C13 to JIS C-8303 (Japan) Line Cord
39Y7922 6214 2.8m, 10A/250V, C13 to SABS 164-1 (South Africa) Line Cord
81Y2379 6576 4.3m, 10A/250V, C13 to SANS 164-1 (South Africa) Line Cord
39Y7926 6335 4.3m, 12A/100V, C13 to JIS C-8303 (Japan) Line Cord
39Y7925 6219 2.8m, 12A/220V, C13 to KSC 8305 (S. Korea) Line Cord
81Y2385 6494 4.3m, 12A/250V, C13 to KSC 8305 (S. Korea) Line Cord
39Y7919 6216 2.8m, 10A/250V, C13 to SEV 1011-S24507 (Swiss) Line Cord
81Y2390 6578 4.3m, 10A/250V, C13 to SEV 1011-S24507 (Swiss) Line Cord
23R7158 6386 2.8m, 10A/125V, C13 to CNS 10917 (Taiwan) Line Cord
81Y2375 6317 2.8m, 10A/250V, C13 to CNS 10917 (Taiwan) Line Cord
81Y2374 6402 2.8m, 13A/125V, C13 to CNS 10917 (Taiwan) Line Cord
4L67A08363 AX8B 4.3m, 10A/125V, C13 to CNS 10917 (Taiwan) Line Cord
81Y2389 6531 4.3m, 10A/250V, C13 to CNS 10917 (Taiwan) Line Cord
81Y2388 6530 4.3m, 13A/125V, C13 to CNS 10917 (Taiwan) Line Cord
39Y7923 6215 2.8m, 10A/250V, C13 to BS 1363/A (UK) Line Cord
81Y2377 6577 4.3m, 10A/250V, C13 to BS 1363/A (UK) Line Cord
90Y3016 6313 2.8M, 10A/125V, C13 to NEMA 5-15P (US) Line Cord
46M2592 A1RF 2.8m, 10A/250V, C13 to NEMA 6-15P (US) Line Cord
00WH545 6401 2.8M, 13A/125V, C13 to NEMA 5-15P (US) Line Cord
4L67A08359 6370 4.3m, 10A/125V, C13 to NEMA 5-15P (US) Line Cord
4L67A08361 6373 4.3m, 10A/250V, C13 to NEMA 6-15P (US) Line Cord
4L67A08360 AX8A 4.3m, 13A/125V, C13 to NEMA 5-15P (US) Line Cord

110V customers: If you plan to use the ThinkSystem 1100W power supply with a 110V power source, select a power cable that is rated above 10A. Power cables that are rated at 10A or below are not supported with 110V power.

The ST550 also supports the following two-up cables.

Table 45. Power cables for ST550
Part number Feature code Description
47C2491 A3SW 1.2m, 10A/100-250V, (2X) C13 to C20 Jumper Cord
47C2492 A3SX 2.5m, 10A/100-250V, (2X) C13 to C20 Jumper Cord
47C2493 A3SY 2.8m, 10A/100-250V, (2X) C13 to C20 Jumper Cord
47C2494 A3SZ 4.1m, 10A/100-250V, (2X) C13 to C20 Jumper Cord

Integrated virtualization

The server supports booting from an operating system or hypervisor installed on an M.2 solid-state drive. See the M.2 drives section for details and the list of available options.

You can download supported VMware vSphere hypervisor images from the following web page and load it on the M.2 drive using the instructions provided:
http://shop.lenovo.com/us/en/systems/solutions/alliances/vmware/#tab-vmware_vsphere_esxi

Systems management

The server contains an integrated service processor, XClarity Controller (XCC), which provides advanced service-processor control, monitoring, and alerting functions. The XCC is based on the Pilot4 XE401 baseboard management controller (BMC) using a dual-core ARM Cortex A9 service processor.

Local management

The ST550 offers a front operator panel showing key LED status indicators, as shown in the following figure.

ST550 front operator panel
Figure 18. Front operator panel

When you press the ID button on the front panel, the blue system ID LEDs on both the front and rear of the server are lit to help you locate the server among other servers. You also can turn on the system ID LEDs using a remote management program for server presence detection.

System status with XClarity Mobile

The XClarity Mobile app now includes a tethering function where you can connect your Android or iOS device to the server via USB to see the status of the server.

The steps to connect the mobile device are as follows:

  1. Enable USB Management on the server, by holding down the ID button for 3 seconds (or pressing the dedicated USB management button if one is present)
  2. Connect the mobile device via a USB cable to the server's USB port with the management symbol USB Management symbol
  3. In iOS or Android settings, enable Personal Hotspot or USB Tethering
  4. Launch the Lenovo XClarity Mobile app

Once connected you can see the following information:

  • Server status including error logs (read only, no login required)
  • Server management functions (XClarity login credentials required)

Remote management

Remote server management is provided through industry-standard interfaces:

  • Intelligent Platform Management Interface (IPMI) Version 2.0
  • Simple Network Management Protocol (SNMP) Version 3 (no SET commands; no SNMP v1)
  • Common Information Model (CIM-XML)
  • Representational State Transfer (REST) support
  • Redfish support (DMTF compliant)
  • Web browser - HTML 5-based browser interface (Java and ActiveX not required) using a responsive design (content optimized for device being used - laptop, tablet, phone) with NLS support

There are two XClarity Controller upgrades available for the server, Advanced and Enterprise.

Lenovo XClarity Controller Advanced adds the following remote control functions:

  • Remotely viewing video with graphics resolutions up to 1600x1200 at 75 Hz with up to 23 bits per pixel, regardless of the system state
  • Remotely accessing the server using the keyboard and mouse from a remote client
  • Capturing blue-screen errors
  • International keyboard mapping support
  • LDAP-based authentication

Lenovo XClarity Controller Enterprise enables the following additional features:

  • Boot Capture
  • Remote mounting of CD-ROM (ISO) and diskette (IMG) files as virtual drives
  • Virtual console collaboration - Ability for up to 6 remote users to be log into the remote session simultaneously
  • Power capping
  • License for XClarity Energy Manager

Preconfigured models come with either XClarity Controller Standard, Advanced or Enterprise, depending on the model. See the Models section for details. The following table shows the field upgrades available for preconfigured models.

Table 46. XClarity Controller field upgrades
Part number Feature code Description
4L47A09132 AVUT ThinkSystem XClarity Controller Standard to Advanced Upgrade
(for servers that have XCC Standard)
4L47A09133 AVUU ThinkSystem XClarity Controller Advanced to Enterprise Upgrade
(for servers that have XCC Advanced)

For configure-to-order (CTO) models, you can elect to have one of the following XCC functionality by selecting the appropriate XCC feature codes as listed in the following table:

  • XCC Standard - select neither feature listed in the table
  • XCC Advanced - select feature AVUT
  • XCC Enterprise - select feature AUPW
Table 47. XClarity Controller Upgrades for configure-to-order
Feature code Description
AVUT ThinkSystem XClarity Controller Standard to Advanced Upgrade
AUPW ThinkSystem XClarity Controller Standard to Enterprise Upgrade

Lenovo XClarity Provisioning Manager

Lenovo XClarity Provisioning Manager is a UEFI-based application embedded in ThinkSystem servers and accessible via the F1 key during system boot.

Lenovo XClarity Provisioning Manager provides the following functions:

  • Graphical UEFI Setup
  • System inventory information and VPD update
  • System firmware updates (UEFI and XCC)
  • RAID setup wizard
  • OS installation wizard (including unattended OS installation)
  • Diagnostics functions

Lenovo XClarity Administrator

Lenovo XClarity Administrator is a centralized resource management solution designed to reduce complexity, speed response, and enhance the availability of Lenovo systems and solutions.

Lenovo XClarity Administrator provides agent-free hardware management for ThinkSystem servers, in addition to ThinkServer, System x, and Flex System servers. The administration dashboard is based on HTML 5 and allows fast location of resources so tasks can be run quickly.

Because Lenovo XClarity Administrator does not require any agent software to be installed on the managed endpoints, there are no CPU cycles spent on agent execution, and no memory is used, which means that up to 1GB of RAM and 1 - 2% CPU usage is saved, compared to a typical managed system where an agent is required.

Lenovo XClarity Administrator provides full management function to ThinkSystem servers, including the following:

  • Discovery
  • Inventory
  • Monitoring and alerting
  • Call home
  • Centralized user management
  • Cryptography modes, server certificates, and encapsulation
  • Configuration patterns
  • Operating system deployment
  • Firmware updates

For more information about Lenovo XClarity Administrator, including ordering part numbers, see the Lenovo XClarity Administrator Product Guide:
https://lenovopress.com/tips1200-lenovo-xclarity-administrator

Lenovo XClarity Essentials

Lenovo offers the following XClarity Essentials software tools that can help you set up, use, and maintain the server at no additional cost:

  • Lenovo Essentials OneCLI

    OneCLI is a collection of server management tools that uses a command line interface program to manage firmware, hardware, and operating systems. It provides functions to collect full system health information (including health status), configure system setting, and update system firmware and drivers.

  • Lenovo Essentials UpdateXpress

    The UpdateXpress tool is a standalone GUI application for firmware and device driver updates that enables you to maintain your server firmware and device drivers up-to-date and help you avoid unnecessary server outages. The tool acquires and deploys individual updates and UpdateXpress System Packs (UXSPs) which are integration-tested bundles.

  • Lenovo Essentials Bootable Media Creator

    The Bootable Media Creator (BOMC) tool is used to create bootable media for offline firmware update.

For more information and downloads, visit the Lenovo XClarity Essentials web page:
http://support.lenovo.com/us/en/documents/LNVO-center

Lenovo XClarity Energy Manager

Lenovo XClarity Energy Manager is an agent-free, web-based console that provides power management for ThinkSystem servers as well as System x and ThinkServer systems. It enables server density and data center capacity to be increased through the use of power capping.

Lenovo XClarity Energy Manager is a licensed product. A single-node XClarity Energy Manager license is included with the XClarity Controller Enterprise (XCC Enterprise) upgrade as described in the Remote Management section. If your server does not have the XCC Enterprise upgrade, Energy Manager licenses can be ordered as shown in the following table.

Table 48. Lenovo XClarity Energy Manager
Description Part number Maximum supported
4L40E51621 Lenovo XClarity Energy Manager Node License 1 node
4L40E51622 Lenovo XClarity Energy Manager Node License Pack 5 nodes
4L40E51623 Lenovo XClarity Energy Manager Node License Pack 50 nodes

Security

The server offers the following security features:

  • Electronic security measures:
    • Administrator and power-on passwords
    • Trusted Platform Module (TPM) supporting both TPM 1.2 and TPM 2.0
    • Optional Trusted Cryptographic Module (TCM), available only in China
    • Self-encrypting drives with support for IBM Security Key Lifecycle Manager
  • Mechanical security measures
    • Lockable side cover to help prevent access to internal components
    • Slot at the rear of the server for a Kensington Cable Lock
    • Optional chassis intrusion switch
    • Optional lockable front security door

The TCM module, available only for China customers, is installed in a dedicated socket on the system board, as shown in Figure 4.

The optional lockable front door includes a key that enables you to secure access to the drive bays and system controls, thereby reducing the possibility of unauthorized or accidental access to the server.

The following table lists the security options for the server.

Table 49. Security features
Part number Feature code Description
7XH7A05903 AVRR ThinkSystem ST550 Security Door
None* AVKE ThinkSystem Trusted Cryptographic Module (China customers only)
None* AVSD ThinkSystem ST550 Intrusion Switch and Cable

* Available via configure-to-order or in preconfigured models only

For SED drives and IBM Security Key Lifecycle Manager support see the SED encryption key management with ISKLM section.

Keyboards and Mice

The following table lists the supported full-sized USB keyboards and mice available for Lenovo ThinkSystem servers.

The keyboards have the following features:

  • Full-sized 104-key keyboard with 3 special Windows keys
  • 3 LEDs for caps lock, scroll lock and num lock
  • Wired USB connection with 1.8m cable
  • Adjustable feet at the rear of the keyboard

Tip: For keyboards that fit in the rack-mounted console kit, see the KVM console options section, or the 1U 18.5-inch Standard Media Console product guide.

Table 50. Lenovo Preferred Pro USB Full-sized keyboards - ThinkSystem
Part number Feature code Description
Mice
7M57A04698 B0LN ThinkSystem Optical Wheel Mouse - USB
Keyboards
7ZB7A05521 AXTM ThinkSystem Pref. Pro Keyboard USB - Arabic 253 RoHS v2
7ZB7A05520 AXTN ThinkSystem Pref. Pro Keyboard USB - Arabic French 462 RoHS v2
7ZB7A05519 AXTP ThinkSystem Pref. Pro Keyboard USB - Belgium/French 120 RoHS v2
7ZB7A05518 AXTQ ThinkSystem Pref. Pro Keyboard USB - Belgium/UK 120 RoHS v2
7ZB7A05517 AXTR ThinkSystem Pref. Pro Keyboard USB - Brazil/Portuguese 275 RoHS v2
7ZB7A05515 AXTS ThinkSystem Pref. Pro Keyboard USB - Bulgarian 442 RoHS v2
7ZB7A05511 AXTU ThinkSystem Pref. Pro Keyboard USB - Czech RoHS v2
7ZB7A05509 AXTV ThinkSystem Pref. Pro Keyboard USB - Danish 159 RoHS v2
7ZB7A05508 AXTW ThinkSystem Pref. Pro Keyboard USB - Dutch 143 RoHS v2
7ZB7A05506 AXTX ThinkSystem Pref. Pro Keyboard USB - French 189 roHS v2
7ZB7A05496 AXTZ ThinkSystem Pref. Pro Keyboard USB - French Canadian 058 French RoHS v2
7ZB7A05504 AXTY ThinkSystem Pref. Pro Keyboard USB - French Canadian 445 Multilingual RoHS v2
7ZB7A05495 AXU0 ThinkSystem Pref. Pro Keyboard USB - German 129 RoHS v2
7ZB7A05494 AXU1 ThinkSystem Pref. Pro Keyboard USB - Greek 319 RoHS v2
7ZB7A05493 AXU2 ThinkSystem Pref. Pro Keyboard USB - Hebrew RoHS v2
7ZB7A05492 AXU3 ThinkSystem Pref. Pro Keyboard USB - Hungarian 208 RoHS v2
7ZB7A05491 AXU4 ThinkSystem Pref. Pro Keyboard USB - Iceland 197 RoHS v2
7ZB7A05490 AXU5 ThinkSystem Pref. Pro Keyboard USB - Italy 141 RoHS v2
7ZB7A05489 AXU6 ThinkSystem Pref. Pro Keyboard USB - Japanese 194 RoHS
7ZB7A05488 AXU7 ThinkSystem Pref. Pro Keyboard USB - Korean 413 RoHS v2
7ZB7A05487 AXU8 ThinkSystem Pref. Pro Keyboard USB - LA Spanish 171 RoHS v2
7ZB7A05486 AXU9 ThinkSystem Pref. Pro Keyboard USB - Norwegian 155 RoHS v2
7ZB7A05485 AXUA ThinkSystem Pref. Pro Keyboard USB - Polish RoHS v2
7ZB7A05484 AXUB ThinkSystem Pref. Pro Keyboard USB - Portugese 163 RoHS v2
7ZB7A05483 AXUC ThinkSystem Pref. Pro Keyboard USB - Romanian RoHS v2
7ZB7A05482 AXUD ThinkSystem Pref. Pro Keyboard USB - Russian/Cyrillic 441 RoHS v2
7ZB7A05481 AXUE ThinkSystem Pref. Pro Keyboard USB - Serbian/Cyrillic RoHS v2
7ZB7A05480 AXUF ThinkSystem Pref. Pro Keyboard USB - Slovak 245 RoHS v2
7ZB7A05471 AXUQ ThinkSystem Pref. Pro Keyboard USB - Slovenian 234 RoHS v2
7ZB7A05479 AXUG ThinkSystem Pref. Pro Keyboard USB - Spanish 172 RoHS v2
7ZB7A05478 AXUH ThinkSystem Pref. Pro Keyboard USB - Swedish/Finn 153 RoHS v2
7ZB7A05477 AXUJ ThinkSystem Pref. Pro Keyboard USB - Swiss F/G 150 RoHS v2
7ZB7A05476 AXUK ThinkSystem Pref. Pro Keyboard USB - Thailand 191 RoHS v2
7ZB7A05513 AXTT ThinkSystem Pref. Pro Keyboard USB - Trad Chinese/US 467 RoHS v2
7ZB7A05474 AXUM ThinkSystem Pref. Pro Keyboard USB - Turkish 179 RoHS v2
7ZB7A05475 AXUL ThinkSystem Pref. Pro Keyboard USB - Turkish 440 RoHS v2
7ZB7A05473 AXUN ThinkSystem Pref. Pro Keyboard USB - UK English 166 RoHS v2
7ZB7A05522 AXTL ThinkSystem Pref. Pro Keyboard USB - US English 103P RoHS v2
7ZB7A05472 AXUP ThinkSystem Pref. Pro Keyboard USB - US Euro 103P RoHS v2

 

Rack installation

The server can be installed in the rack with the Tower to Rack Conversion Kit. The resulting server is a 4U rack-mountable server, as shown in the following figure.

ThinkSystem ST550 Rack Conversion
Figure 19. ThinkSystem ST550 with Rack Conversion Kit installed

The part numbers are summarized in the following table.

Table 51. Rack installation options
Part
number
Feature
code
Description
7XH7A05901 AVRZ ThinkSystem ST550 4U Tower to Rack Conversion Kit
7XH7A05902 AVRX ThinkSystem ST550 CMA Kit

The rail kit has the specifications listed in the following table.

Table 52. Rail kit specifications
Feature ThinkSystem ST550 4U Tower to Rack Conversion Kit
Part number 7XH7A05901
Rail type Full-out slide rail (ball bearing)
Toolless installation Yes
Cable Management Arm (CMA) support Optional (7XH7A05902)
In-rack server maintenance Yes
1U PDU support Yes
0U PDU support Limited*
Rack type Lenovo and IBM 4-post, IEC standard-compliant
Mounting holes Square or round
Mounting flange thickness 2 mm - 3.3 mm (0.08 - 0.13 in.)
Distance between front and rear mounting flanges 537 mm - 810 mm (21.1 - 31.9 in.)
Rail length*** 792 mm (31.2 in.)

 * For 0U PDU support, the rack must be at least 1100 mm (43.31 in.) deep without a CMA, or at least 1200 mm (47.24 in.) deep if a CMA is used.
*** Measured when mounted on the rack, from the front surface of the front mounting flange to the rearmost point of the rail.

Supported rack cabinets are listed in the Rack cabinets section.

Operating system support

The server supports the following operating systems:

  • Microsoft Windows Server 2012 R2
  • Microsoft Windows Server 2016
  • SUSE Linux Enterprise Server 11 SP4
  • SUSE Linux Enterprise Server 12 SP2
  • Red Hat Enterprise Linux 6.9
  • Red Hat Enterprise Linux 7.3
  • VMware ESXi 6.0 U3
  • VMware ESXi 6.5

For details about the specific versions and service levels supported and any other prerequisites, see the Operating System Interoperability Guide: http://lenovopress.com/osig

Virtualization support: The onboard SATA ports of the server can be used with virtualization hypervisors, including VMware ESXi, Linux KVM, Xen, and Microsoft Hyper-V, however support is limited to AHCI (non-RAID) mode. RSTe mode is not supported with virtualization hypervisors.

For configure-to-order configurations, the server can be preloaded with VMware ESXi installed on M.2 cards. Ordering information is listed in the following table.

Table 53. VMware ESXi preload
Part number Feature code Description
CTO only AXFT VMware ESXi 6.5 (factory installed)
CTO only AXFS VMware ESXi 6.0 U3 (factory installed)

Physical and electrical specifications

The server features the following dimensions and weight:

  • Tower:
    • Width with stabilizer feet extended: 272 mm (10.7 in)
    • Width with stabilizer feet retracted: 176 mm (6.9 in)
    • Depth: 670 mm (26.4 in)
    • Height: 438 mm (17.2 in)
  • With rack conversion kit:
    • Width: 482 mm (18.97 inches)
    • Depth: 670 mm (26.4 in)
    • Height: 176 mm (6.9 in)

Weight:

  • Fully configured: 36 kg (79.36 lb)

A note about the stabilizer feet: The ST550 includes stabilizer foot stands that are used when the server is in the tower configuration. The stabilizer feet can be installed in a retracted position or in an open position. For safety reasons, it is recommended the feet be used in the open position to help prevent the server from tipping over, however if needed, the feet can be positioned so that they do not extend beyond the width of the server enclosure. When the ST550 is converted to a rack configuration, the feet are removed.

Electrical requirements are as follows:

  • Models with 550 W AC power supplies:
    • 100-127 (nominal) V ac; 50 Hz or 60 Hz; 6.2 A
    • 200 - 240 (nominal) V ac; 50 Hz or 60 Hz; 3.0 A
    • Input kilovolt-amperes (kVA) (approximately):
      • Minimum configuration: 0.16 kVA
      • Maximum configuration: 0.722 kVA
  • Models with 750 W Platinum AC power supplies:
    • 100 - 127 (nominal) V ac; 50 Hz or 60 Hz; 8.4 A
    • 200 - 240 (nominal) V ac; 50 Hz or 60 Hz; 4.1 A
    • Input kilovolt-amperes (kVA) (approximately):
      • Minimum configuration: 0.15 kVA
      • Maximum configuration: 0.954 kVA
  • Models with 750 W Titanium AC power supplies:
    • 200 - 240 (nominal) V ac; 50 Hz or 60 Hz; 4.1 A
    • Input kilovolt-amperes (kVA) (approximately):
      • Minimum configuration: 0.15 kVA
      • Maximum configuration: 0.906 kVA
  • Models with 1100 W Platinum AC power supplies:
    • 100 - 127 (nominal) V ac; 50 Hz or 60 Hz; 12.0 A
    • 200 - 240 (nominal) V ac; 50 Hz or 60 Hz; 6.0 A
    • Input kilovolt-amperes (kVA) (approximately):
      • Minimum configuration:  0.12 kVA
      • Maximum configuration: 1.406 kVA

For China customers using 240V DC input power:

  • Models with 550 W 240V DC power supplies:
    • 200 - 240 (nominal) V dc; 2.5 A
    • Input kilovolt-amperes (kVA) (approximately):
      • Minimum configuration: 0.16 kVA
      • Maximum configuration: 0.70 kVA
  • Models with 750 W Platinum 240V DC power supplies:
    • 200 - 240 (nominal) V dc; 3.5 A
    • Input kilovolt-amperes (kVA) (approximately):
      • Minimum configuration: 0.15 kVA
      • Maximum configuration: 0.958 kVA
  • Models with 750 W Titanium 240V DC power supplies:
    • 200 - 240 (nominal) V dc; 3.5 A
    • Input kilovolt-amperes (kVA) (approximately):
      • Minimum configuration: 0.15 kVA
      • Maximum configuration: 0.948 kVA
  • Models with 1100 W Platinum 240V DC power supplies:
    • 200 - 240 (nominal) V dc; 5.1 A
    • Input kilovolt-amperes (kVA) (approximately):
      • Minimum configuration:  0.12 kVA
      • Maximum configuration: 1.408 kVA

Operating environment

The ThinkSystem ST550 server complies with ASHRAE Class A2 specifications, and depending on the hardware configuration, also complies with ASHRAE Class A3 and Class A4 specifications. System performance may be impacted when operating temperature is outside ASHRAE A2 specification.

The following restrictions apply with ASHRAE A4 and A3 support:

  • No support for processors with TDP rating of 125 W or higher
  • Two power supplies must be installed; fixed (cabled) power supply not supported
  • The rear fan must be installed
  • No support for NVMe drives
  • No support for GPUs
  • If the media bay conversion kit is installed (adding 4x 2.5-inch drive bays), those drive bays cannot support SAS drives (HDD or SSD) that are 2TB or larger. SATA drives are fully supported.

In addition, CPU core speed may be reduced depending on the processor selected. 

The server is supported operating in the following environments:

  • ASHRAE A2:
    • Temperature: 10°C to 35°C
    • Humidity: 20% to 80%
    • Altitude 0-3000 m (10,000 ft), derated 1°C per 300 m above 950 m
  • ASHRAE A3:
    • Temperature: 5°C to 40°C
    • Humidity: 8% to 85%
    • Altitude 0-3000 m (10,000 ft), derated 1°C per 175 m above 950 m
  • ASHRAE A4:
    • Temperature: 5°C to 45°C
    • Humidity: 8% to 90%
    • Altitude 0-3000 m (10,000 ft), derated 1°C per 125 m above 950 m

Non-operating environment support:

  • Without packaging:
    • Temperature: -10 °C to 60 °C
    • Humidity: 8 to 90%
  • Storage with packaging:
    • Temperature: -40 °C to 70 °C
    • Humidity: 8 to 90%

Thermal (heat) output:

  • Maximum configuration: 4074 Btu/hr (1194 watts)

Acoustical noise emissions:

  • Sound power levels (bels):
    • Base configuration: 4.0 bels (idle), 4.1 bels (operating)
    • Maximum configuration: 5.3 bels (idle), 5.3 bels (operating)
  • Sound pressure levels (dBA):
    • Base configuration: 33 dBA (idle), 33 dBA (operating)
    • Maximum configuration: 43 dBA (idle), 43 dBA (operating)

The server has the following vibration and shock limits:

  • Vibration:
    • Operating: 0.21 G rms at 5 Hz to 500 Hz for 15 minutes across 3 axes
    • Non-operating: 1.04 G rms at 2 Hz to 200 Hz for 15 minutes across 6 surfaces
  • Shock:
    • Operating: 15 G for 3 milliseconds in each direction (positive and negative X, Y, and Z axes)
    • Non-operating:
      • 12 kg - 22 kg: 50 G for 152 in./sec velocity change across 6 surfaces
      • 23 kg  - 31 kg: 35 G for 152 in./sec velocity change across 6 surfaces

Warranty options

The ST550 has a 1-year or 3-year warranty, based on the machine type of the system:

  • 7X09: 1 year warranty
  • 7X10: 3 year warranty

The standard warranty terms are customer-replaceable unit (CRU) and onsite (for field-replaceable units, FRUs, only) with standard call center support during normal business hours and 9x5 Next Business Day Parts Delivered.

Also available are Lenovo Services warranty maintenance upgrades and post-warranty maintenance agreements, with a predefined scope of services, including service hours, response time, term of service, and service agreement terms and conditions.

Lenovo warranty service upgrade offerings are country-specific. Not all warranty service upgrades are available in every country. For more information about Lenovo warranty service upgrade offerings that are available in your country, go to the Data Center Advisor and Configurator (formerly known as LESC) website http://lesc.lenovo.com, then do the following:

  1. In the Customize a Model box in the middle of the page, select the Services option in the Customization Option dropdown menu
  2. Enter the machine type & model of the system
  3. From the search results, you can click either Deployment Services or Support Services to view the offerings

The following table explains warranty service definitions in more detail.

Table 54. Warranty service definitions
Term Description
Onsite Service If a problem with your product cannot be resolved via telephone, a Service Technician will be dispatched to arrive at your location. 
Parts Delivered If a problem with your product cannot be resolved via telephone and a CRU part is required, Lenovo will send a replacement CRU to arrive at your location. If a problem with your product cannot be resolved via telephone and a FRU part is required, a Service Technician will be dispatched to arrive at your location.  
Technician Installed Parts If a problem with your product cannot be resolved via telephone, a Service Technician will be dispatched to arrive at your location.
Hours of coverage
  • 9x5: 9 hours/day, 5 days/week, during normal business hours, excluding local public & national holidays
  • 24x7: 24 hours per day, 7 days per week, 365 days per year.
Response time target 2 hours, 4 hours, or Next Business Day: The time period from when the telephone based troubleshooting is completed and logged, to the delivery of the CRU or arrival of a Service Technician and part at the Customer’s location for repair.
Committed Repair 6 hours: The time period between the service request registration in Lenovo’s call management system and the restoration of the product to conformance with its specification by a Service Technician. 

The following Lenovo warranty service upgrades are available:

  • Warranty and maintenance service upgrades:
    • Three, four, or five years of 9x5 or 24x7 service coverage
    • Parts delivered or technician installed parts from next business day to 4 or 2 hours
    • Committed repair service
    • Warranty extension of up to 5 years
    • Post warranty extensions
  • Committed Repair Service

    Committed Repair Services enhances the level of Warranty Service Upgrade or Post Warranty/Maintenance Service offering associated with the selected systems. Offerings vary and are available in select countries.

    • Priority handling to meet defined time frames to restore the failing machine to good working condition
    • 24x7x6 committed repair: Service performed 24 hours per day, 7 days per week, within 6 hours
  • YourDrive YourData

    Lenovo’s YourDrive YourData service is a multi-drive retention offering that ensures your data is always under your control, regardless of the number of drives that are installed in your Lenovo server. In the unlikely event of a drive failure, you retain possession of your drive while Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands. The YourDrive YourData service can be purchased in convenient bundles with Lenovo warranty upgrades and extensions.

  • Microcode Support

    Keeping microcode current helps prevent hardware failures and security exposure. There are two levels of service: analysis of the installed base and analysis and update where required. Offerings vary by country and can be bundled with other warranty upgrades and extensions.

  • Enterprise Software Support

    Lenovo Enterprise Server Software Support can help you troubleshoot your entire server software stack. Choose support for server operating systems from Microsoft, Red Hat, SUSE, and VMware; Microsoft server applications; or both operating systems and applications. Support staff can help answer troubleshooting and diagnostic questions, address product compatibility and interoperability issues, isolate causes of problems, report defects to software vendors, and more.

    In addition, you can access hardware “how to” support for ThinkSystem servers. Staff can help resolve hardware problems not covered under warranty, refer you to the right documentation and publications, provide corrective service information for known defects, and transfer you to a hardware support call center if needed.

  • Hardware Installation Services

    Lenovo experts can seamlessly manage the physical installation of your server, storage, or networking hardware. Working at a time convenient for you (business hours or off shift), the technician will unpack and inspect the systems on your site, install options, mount in a rack cabinet, connect to power and network, check and update firmware to the latest levels, verify operation, and dispose of the packaging, allowing your team to focus on other priorities. Your new systems will be configured and ready for your software installation.

Regulatory compliance

The ST550 server conforms to the following standards:

  • Energy Star 2.1
  • FCC - Verified to comply with Part 15 of the FCC Rules, Class A
  • Canada ICES-003, issue 6, Class A
  • UL/IEC 60950-1
  • CSA C22.2 No. 60950-1
  • IEC 62368-1:2014 (CB Certificate and CB Test Report)
  • NOM-019
  • Argentina IEC60950-1
  • Japan VCCI, Class A
  • Australia/New Zealand AS/NZS CISPR 32, Class A; AS/NZS 60950.1
  • China CCC GB4943.1, GB9254 Class A, GB17625.1
  • Taiwan BSMI CNS13438, Class A; CNS14336-1; CNS15663
  • Korea KN32, Class A; KN35
  • Russia, Belorussia and Kazakhstan, TR CU 020/2011 (for EMC) and TR CU 004/2011 (for safety)
  • IEC 60950-1 (CB Certificate and CB Test Report)
  • CE Mark (EN55032 Class A, EN60950-1, EN55024, EN61000-3-2, EN61000-3-3)
  • CISPR 32, Class A
  • TUV-GS (EN60950-1 /IEC60950-1,EK1-ITB2000)
  • RoHS Directive
  • ErP lot3
  • JESL

External drive enclosures

The server supports attachment to external drive enclosures using a RAID controller with external ports or a SAS host bus adapter. Adapters supported by the server are listed in the SAS adapters for external storage section.

The following table lists the 6 Gbps SAS external drive enclosures that are offered by Lenovo that can be used with the server for storage expansion.

Table 55. E1012 and E1024 external drive enclosure models
Part number Description
64111B1 Lenovo Storage E1012 LFF Disk Expansion Single SAS IO Module, Rail Kit, 9x5 NBD
64111B2 Lenovo Storage E1012 LFF Disk Expansion Dual SAS IO Module, Rail Kit, 9x5 NBD
64111B3 Lenovo Storage E1024 SFF Disk Expansion Single SAS IO Module, Rail Kit, 9x5 NBD
64111B4 Lenovo Storage E1024 SFF Disk Expansion Dual SAS IO Module, Rail Kit, 9x5 NBD

For details about supported drives and cables for the Lenovo Storage E1012 and E1024, see the Lenovo Press Product Guide:
http://lenovopress.com/lp0043

The following table lists the standard models of the 12 Gbps SAS external drive enclosures offered by Lenovo that can be used with the server for storage expansion.

Table 56. D1212 and D1224 standard models
Part number Description
LFF models
4587A11* D1212 LFF Chassis, Dual 3-port ESMs (US English documentation)
4587A1C^ D1212 LFF Chassis, Dual 3-port ESMs (Simplified Chinese documentation)
4587A1J** D1212 LFF Chassis, Dual 3-port ESMs (Japanese documentation)
SFF models
4587A31* D1224 SFF Chassis, Dual 3-port ESMs (US English documentation)
4587A3C^ D1224 SFF Chassis, Dual 3-port ESMs (Simplified Chinese documentation)
4587A3J** D1224 SFF Chassis, Dual 3-port ESMs (Japanese documentation)

* Available worldwide (except China and Japan)
^ Available only in China
** Available only in Japan

The following table lists the TopSeller models of the 12 Gbps SAS external drive enclosures offered by Lenovo that can be used with the server for storage expansion.

Table 57. D1212 and D1224 TopSeller models
Part number Description
Brazil and Latin America - LFF models
4587EAU D1212 LFF Chassis, Dual 3-port ESMs, 4x 2TB 3.5" HDDs, 4x 0.5m SAS cables
4587EBU D1212 LFF Chassis, Dual 3-port ESMs, 4x 4TB 3.5" HDDs, 4x 0.5m SAS cables
4587ECU D1212 LFF Chassis, Dual 3-port ESMs, 4x 6TB 3.5" HDDs, 4x 0.5m SAS cables
4587EDU D1212 LFF Chassis, Dual 3-port ESMs, 4x 8TB 3.5" HDDs, 4x 0.5m SAS cables
4587EEU D1212 LFF Chassis, Dual 3-port ESMs, 8x 2TB 3.5" HDDs, 4x 0.5m SAS cables
4587EFU D1212 LFF Chassis, Dual 3-port ESMs, 8x 4TB 3.5" HDDs, 4x 0.5m SAS cables
4587EGU D1212 LFF Chassis, Dual 3-port ESMs, 8x 6TB 3.5" HDDs, 4x 0.5m SAS cables
4587EHU D1212 LFF Chassis, Dual 3-port ESMs, 8x 8TB 3.5" HDDs, 4x 0.5m SAS cables
4587EIU D1212 LFF Chassis, Dual 3-port ESMs, 12x 2TB 3.5" HDDs, 4x 0.5m SAS cables
4587EJU D1212 LFF Chassis, Dual 3-port ESMs, 12x 4TB 3.5" HDDs, 4x 0.5m SAS cables
4587EKU D1212 LFF Chassis, Dual 3-port ESMs, 12x 6TB 3.5" HDDs, 4x 0.5m SAS cables
4587ELU D1212 LFF Chassis, Dual 3-port ESMs, 12x 8TB 3.5" HDDs, 4x 0.5m SAS cables
Brazil and Latin America - SFF models
4587E6U D1224 SFF Chassis, Dual 3-port ESMs, 9x 1.2TB 10K HDDs, 4x 0.5m SAS cables
4587E2U D1224 SFF Chassis, Dual 3-port ESMs, 9x 1.2TB 10K HDDs, 2x 400GB SSDs, 4x 0.5m SAS cables
4587E4U D1224 SFF Chassis, Dual 3-port ESMs, 9x 1.2TB 10K HDDs, 4x 400GB SSDs, 4x 0.5m SAS cables
4587E5U D1224 SFF Chassis, Dual 3-port ESMs, 18x 1.2TB 10K HDDs, 1x 0.5m SAS cable
4587E1U D1224 SFF Chassis, Dual 3-port ESMs, 18x 1.2TB 10K HDDs, 2x 400GB SSDs, 4x 0.5m SAS cables
4587E3U D1224 SFF Chassis, Dual 3-port ESMs, 18x 1.2TB 10K HDDs, 4x 400GB SSDs, 4x 0.5m SAS cables

For details about supported drives and cables for the Lenovo Storage D1212 and D1224, see the Lenovo Press Product Guide:
http://lenovopress.com/lp0512

The following table lists the standard models of the 12 Gbps SAS external high density drive enclosures offered by Lenovo.

Table 58. D3284 standard models
Description Part number
Lenovo Storage D3284 4TB x 84 HD Expansion Enclosure 641311F
Lenovo Storage D3284 6TB x 84 HD Expansion Enclosure 641312F
Lenovo Storage D3284 8TB x 84 HD Expansion Enclosure 641313F
Lenovo Storage D3284 10TB x 84 HD Expansion Enclosure 641314F

The following table lists the TopSeller models of the 12 Gbps SAS external high density drive enclosures offered by Lenovo.

Table 59. D3284 TopSeller models
Description Part number
Lenovo Storage D3284 High Density Expansion Enclosure 6413E5F
Lenovo Storage D3284 4TB x 42 HD Expansion Enclosure 6413E1H
Lenovo Storage D3284 4TB x 84 HD Expansion Enclosure 6413E1F
Lenovo Storage D3284 6TB x 42 HD Expansion Enclosure 6413E2H
Lenovo Storage D3284 6TB x 84 HD Expansion Enclosure 6413E2F
Lenovo Storage D3284 8TB x 42 HD Expansion Enclosure 6413E3H
Lenovo Storage D3284 8TB x 84 HD Expansion Enclosure 6413E3F
Lenovo Storage D3284 10TB x 42 HD Expansion Enclosure 6413E4H
Lenovo Storage D3284 10TB x 84 HD Expansion Enclosure 6413E4F

For details about supported drives, adapters, and cables for the Lenovo Storage D3284, see the Lenovo Press Product Guide:
http://lenovopress.com/lp0513

External storage systems

The following table lists the NAS and SAN external storage systems that are offered by Lenovo.

Table 60. External storage systems
Part number Description
Lenovo ThinkSystem DS Series Storage (SAS host connectivity)
4599A41* Lenovo ThinkSystem DS2200 LFF SAS Dual Controller Unit (US English documentation)
4599A4C^ Lenovo ThinkSystem DS2200 LFF SAS Dual Controller Unit (Simplified Chinese documentation)
4599A4J** Lenovo ThinkSystem DS2200 LFF SAS Dual Controller Unit (Japanese documentation)
4599A21* Lenovo ThinkSystem DS2200 SFF SAS Dual Controller Unit (US English documentation)
4599A2C^ Lenovo ThinkSystem DS2200 SFF SAS Dual Controller Unit (Simplified Chinese documentation)
4599A2J** Lenovo ThinkSystem DS2200 SFF SAS Dual Controller Unit (Japanese documentation)
4617A41* Lenovo ThinkSystem DS4200 LFF SAS Dual Controller Unit (US English documentation)
4617A4C^ Lenovo ThinkSystem DS4200 LFF SAS Dual Controller Unit (Simplified Chinese documentation)
4617A4J** Lenovo ThinkSystem DS4200 LFF SAS Dual Controller Unit (Japanese documentation)
4617A21* Lenovo ThinkSystem DS4200 SFF SAS Dual Controller Unit (US English documentation)
4617A2C^ Lenovo ThinkSystem DS4200 SFF SAS Dual Controller Unit (Simplified Chinese documentation)
4617A2J** Lenovo ThinkSystem DS4200 SFF SAS Dual Controller Unit (Japanese documentation)
4619A21* Lenovo ThinkSystem DS6200 SFF SAS Dual Controller Unit (US English documentation)
4619A2C^ Lenovo ThinkSystem DS6200 SFF SAS Dual Controller Unit (Simplified Chinese documentation)
4619A2J** Lenovo ThinkSystem DS6200 SFF SAS Dual Controller Unit (Japanese documentation)
Lenovo ThinkSystem DS Series Storage (iSCSI or FC host connectivity)
4599A31* Lenovo ThinkSystem DS2200 LFF FC/iSCSI Dual Controller Unit (US English documentation)
4599A3C^ Lenovo ThinkSystem DS2200 LFF FC/iSCSI Dual Controller Unit (Simplified Chinese documentation)
4599A3J** Lenovo ThinkSystem DS2200 LFF FC/iSCSI Dual Controller Unit (Japanese documentation)
4599A11* Lenovo ThinkSystem DS2200 SFF FC/iSCSI Dual Controller Unit (US English documentation)
4599A1C^ Lenovo ThinkSystem DS2200 SFF FC/iSCSI Dual Controller Unit (Simplified Chinese documentation)
4599A1J** Lenovo ThinkSystem DS2200 SFF FC/iSCSI Dual Controller Unit (Japanese documentation)
4617A31* Lenovo ThinkSystem DS4200 LFF FC/iSCSI Dual Controller Unit (US English documentation)
4617A3C^ Lenovo ThinkSystem DS4200 LFF FC/iSCSI Dual Controller Unit (Simplified Chinese documentation)
4617A3J** Lenovo ThinkSystem DS4200 LFF FC/iSCSI Dual Controller Unit (Japanese documentation)
4617A11* Lenovo ThinkSystem DS4200 SFF FC/iSCSI Dual Controller Unit (US English documentation)
4617A1C^ Lenovo ThinkSystem DS4200 SFF FC/iSCSI Dual Controller Unit (Simplified Chinese documentation)
4617A1J** Lenovo ThinkSystem DS4200 SFF FC/iSCSI Dual Controller Unit (Japanese documentation)
4619A11* Lenovo ThinkSystem DS6200 SFF FC/iSCSI Dual Controller Unit (US English documentation)
4619A1C^ Lenovo ThinkSystem DS6200 SFF FC/iSCSI Dual Controller Unit (Simplified Chinese documentation)
Lenovo Storage V Series (iSCSI, FC, or FCoE host connectivity)
6535C1D Lenovo Storage V3700 V2 LFF Control Enclosure
6535EC1 Lenovo Storage V3700 V2 LFF Control Enclosure (TopSeller)
6535C2D Lenovo Storage V3700 V2 SFF Control Enclosure
6535EC2 Lenovo Storage V3700 V2 SFF Control Enclosure (TopSeller)
6535C3D Lenovo Storage V3700 V2 XP LFF Control Enclosure
6535EC3 Lenovo Storage V3700 V2 XP LFF Control Enclosure (TopSeller)
6535C4D Lenovo Storage V3700 V2 XP SFF Control Enclosure
6535EC4 Lenovo Storage V3700 V2 XP SFF Control Enclosure (TopSeller)
6536C12 Lenovo Storage V5030 LFF Control Enclosure 3Yr S&S
6536C32 Lenovo Storage V5030 LFF Control Enclosure 5Yr S&S
6536C22 Lenovo Storage V5030 SFF Control Enclosure 3Yr S&S
6536C42 Lenovo Storage V5030 SFF Control Enclosure 5Yr S&S
6536B1F Lenovo Storage V5030F SFF Control Enclosure 3Yr S&S
6536B2F Lenovo Storage V5030F SFF Control Enclosure 5Yr S&S
IBM Storwize for Lenovo (iSCSI, FC, or FCoE host connectivity)
6096CU2^ IBM Storwize V3500 3.5-inch Dual Control Storage Controller Unit
6096CU3^ IBM Storwize V3500 2.5-inch Dual Control Storage Controller Unit
6099L2C IBM Storwize V3700 3.5-inch Storage Controller Unit
6099S2C IBM Storwize V3700 2.5-inch Storage Controller Unit
6195SC5† IBM Storwize V7000 2.5-inch Storage Controller Unit, w/3 Yr S&S (Model 524)
6195SCL‡ IBM Storwize V7000 2.5-inch Storage Controller Unit, w/3 Yr S&S (LA) (Model 524)
61951F1† IBM Storwize V7000 2.5-inch Storage Controller Unit, w/5 Yr S&S (Model 524)
61951FL‡ IBM Storwize V7000 2.5-inch Storage Controller Unit, w/5 Yr S&S (LA) (Model 524)
6195C32† IBM Storwize V7000 SFF Control Enclosure, 3YR SWMA (Model HC1 [Gen2+])
6195C3L‡ IBM Storwize V7000 SFF Control Enclosure, 3YR SWMA, LA (Model HC1 [Gen2+])
6195C52† IBM Storwize V7000 SFF Control Enclosure, 5YR SWMA (Model HC1 [Gen2+])
6195C5L‡ IBM Storwize V7000 SFF Control Enclosure, 5YR SWMA, LA (Model HC1 [Gen2+])
Lenovo Storage DX8200 Series (S3 cloud storage)
5120D1x Lenovo Storage DX8200C 56TB (14x 4TB HDDs) with Cloudian HyperStore - 3yr HW/SW S&S
5120D2x Lenovo Storage DX8200C 84TB (14x 6TB HDDs) with Cloudian HyperStore - 3yr HW/SW S&S
5120D3x Lenovo Storage DX8200C 112TB (14x 8TB HDDs) with Cloudian HyperStore - 3yr HW/SW S&S
5120D4x Lenovo Storage DX8200C 140TB (14x 10TB HDDs) with Cloudian HyperStore - 3yr HW/SW S&S
51205Dx Lenovo Storage DX8200C 168TB (14x 12TB HDDs) with Cloudian HyperStore - 3yr HW/SW S&S
Lenovo Storage DX8200 Series (NAS, iSCSI connectivity; optional FC connectivity)
5135A3x Lenovo Storage DX8200D Storage Virtualization Entry, 4TB, 3yr SW S&S
5135J3x Lenovo Storage DX8200D Storage Virtualization Entry, 4TB, 4yr SW S&S
51351Wx Lenovo Storage DX8200D Storage Virtualization Entry, 4TB, 5yr SW S&S
5135B3x Lenovo Storage DX8200D Storage Virtualization Mid, 16TB, 3yr SW S&S
5135L3x Lenovo Storage DX8200D Storage Virtualization Mid, 16TB, 4yr SW S&S
51352Wx Lenovo Storage DX8200D Storage Virtualization Mid, 16TB, 5yr SW S&S
5135C3x Lenovo Storage DX8200D Storage Virtualization High, 64TB, 3yr SW S&S
5135M3x Lenovo Storage DX8200D Storage Virtualization High, 64TB, 4yr SW S&S
51353Wx Lenovo Storage DX8200D Storage Virtualization High, 64TB, 5yr SW S&S
5135D3x Lenovo Storage DX8200D ServerSAN Entry, 8TB, 3yr SW S&S
5135N3x Lenovo Storage DX8200D ServerSAN Entry, 8TB, 4yr SW S&S
51354Wx Lenovo Storage DX8200D ServerSAN Entry, 8TB, 5yr SW S&S
5135F3x Lenovo Storage DX8200D ServerSAN Mid, 16TB, 3yr SW S&S
5135P3x Lenovo Storage DX8200D ServerSAN Mid, 16TB, 4yr SW S&S
51355Wx Lenovo Storage DX8200D ServerSAN Mid, 16TB, 5yr SW S&S
5135G3x Lenovo Storage DX8200D ServerSAN High, 32TB, 3yr SW S&S
5135Q3x Lenovo Storage DX8200D ServerSAN High, 32TB, 4yr SW S&S
51356Wx Lenovo Storage DX8200D ServerSAN High, 32TB, 5yr SW S&S
5128C1x Lenovo Storage DX8200N with 1x N2226 HBA
5128C2x Lenovo Storage DX8200N with 2x N2226 HBAs

* Available worldwide (except China and Japan).
^ Available only in China.
** Available only in Japan.
† Available worldwide except Latin America.
‡ Available only in Latin America.

For more information, see the list of Product Guides in the following categories:

Top-of-rack Ethernet switches

The following table lists the Ethernet LAN switches that are offered by Lenovo.

Table 61. Ethernet LAN switches
Part number Description
1 Gb Ethernet switches
7165H1X Juniper EX2300-C PoE Switch
7165H2X Juniper EX2300-24p PoE Switch
7159BAX Lenovo RackSwitch G7028 (Rear to Front)
7159CAX Lenovo RackSwitch G7052 (Rear to Front)
7159G52 Lenovo RackSwitch G8052 (Rear to Front)
10 Gb Ethernet switches
7159A1X Lenovo ThinkSystem NE1032 RackSwitch (Rear to Front)
7159B1X Lenovo ThinkSystem NE1032T RackSwitch (Rear to Front)
7159C1X Lenovo ThinkSystem NE1072T RackSwitch (Rear to Front)
7159BR6 Lenovo RackSwitch G8124E (Rear to Front)
7159G64 Lenovo RackSwitch G8264 (Rear to Front)
7159DRX Lenovo RackSwitch G8264CS (Rear to Front)
7159CRW Lenovo RackSwitch G8272 (Rear to Front)
7159GR6 Lenovo RackSwitch G8296 (Rear to Front)
25 Gb Ethernet switches
7159E1X Lenovo ThinkSystem NE2572 RackSwitch (Rear to Front)
40 Gb Ethernet switches
7159BRX Lenovo RackSwitch G8332 (Rear to Front)
100 Gb Ethernet switches
7159D1X Lenovo ThinkSystem NE10032 RackSwitch (Rear to Front)

For more information, see the list of Product Guides in the following switch categories:

Fibre Channel SAN switches

The following table lists the Fibre Channel SAN switches that are offered by Lenovo and can be used with this system.

Table 62. Fibre Channel SAN switches
Part number Description
8 Gb FC
3873AR3 Lenovo B300, 8 ports activated, 8x 8Gb SWL SFPs, 1 PS, Rail Kit
3873AR4 Lenovo B6505, 12 ports activated, 12x 8Gb SWL SFPs, 1 PS, Rail Kit
3873BR2 Lenovo B6510, 24 ports activated, 24x 8Gb SWL SFPs, 2 PS, Rail Kit
16 Gb FC
6559D2Y Lenovo ThinkSystem DB610S, 8 ports activated, 8x 16Gb SWL SFPs, 1 PS, Rail Kit
6559D1Y Lenovo ThinkSystem DB610S, 24 ports activated, 24x 16Gb SWL SFP, Enterprise SW, 1 PS, Rail Kit
3873AR5 Lenovo B6505, 12 ports activated w/ 16Gb SWL SFPs, 1 PS, Rail Kit
3873BR3 Lenovo B6510, 24 ports activated w/ 16Gb SWL SFPs, 2 PS, Rail Kit
32 Gb FC
6559D3Y Lenovo ThinkSystem DB610S, 8 ports activated, 1 PS, Rail Kit
6415G11 Lenovo ThinkSystem DB620S, 24 Ports Activated, 24x 32Gb SWL SFPs, 2 PS, Rail Kit
6415G2A Lenovo ThinkSystem DB620S, 48 Ports Activated, 48x 32Gb SWL SFPs, 2 PS, Rail Kit
6684B2A Lenovo ThinkSystem DB400D 32Gb FC Director, up to 192 ports, 8U, Enterprise SW
6682B1A Lenovo ThinkSystem DB800D 32Gb FC Director, up to 384 ports, 14U, Enterprise SW

For more information, see the list of Product Guides in the Rack SAN Switches category:
http://lenovopress.com/storage/switches/rack?rt=product-guide

Uninterruptible power supply units

The server supports attachments to the uninterruptible power supply (UPS) units that are listed in the following table.

Table 63. Uninterruptible power supply units
Part number Description
Tower UPS units
55951AX T1kVA Tower UPS (100-125VAC)
55951KX T1kVA Tower UPS (200-240VAC)
55952AX T1.5kVA Tower UPS (100-125VAC)
55952KX T1.5kVA Tower UPS (200-240VAC)
Rack-mounted or tower UPS units
55941AX RT1.5kVA 2U Rack or Tower UPS (100-125VAC)
55941KX RT1.5kVA 2U Rack or Tower UPS (200-240VAC)
55942AX RT2.2kVA 2U Rack or Tower UPS (100-125VAC)
55942KX RT2.2kVA 2U Rack or Tower UPS (200-240VAC)
55943AX RT3kVA 2U Rack or Tower UPS (100-125VAC)
55943KX RT3kVA 2U Rack or Tower UPS (200-240VAC)
55945KX RT5kVA 3U Rack or Tower UPS (200-240VAC)
55946KX RT6kVA 3U Rack or Tower UPS (200-240VAC)
55948KX RT8kVA 6U Rack or Tower UPS (200-240VAC)
55949KX RT11kVA 6U Rack or Tower UPS (200-240VAC)
55948PX RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)
55949PX RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)

For more information, see the list of Product Guides in the UPS category:
https://lenovopress.com/servers/options/ups

Power distribution units

The following table lists the power distribution units (PDUs) that are offered by Lenovo.

Table 64. Power distribution units
Part number Description
0U Basic PDUs
00YJ776 0U 36 C13/6 C19 24A/200-240V 1 Phase PDU with NEMA L6-30P line cord
00YJ777 0U 36 C13/6 C19 32A/200-240V 1 Phase PDU with IEC60309 332P6 line cord
00YJ778 0U 21 C13/12 C19 32A/200-240V/346-415V 3 Phase PDU with IEC60309 532P6 line cord
00YJ779 0U 21 C13/12 C19 48A/200-240V 3 Phase PDU with IEC60309 460P9 line cord
Switched and Monitored PDUs
00YJ780 0U 20 C13/4 C19 Switched and Monitored 32A/200-240V/1Ph PDU w/ IEC60309 332P6 line cord
00YJ781 0U 20 C13/4 C19 Switched and Monitored 24A/200-240V/1Ph PDU w/ NEMA L6-30P line cord
00YJ782 0U 18 C13/6 C19 Switched / Monitored 32A/200-240V/346-415V/3Ph PDU w/ IEC60309 532P6 cord
00YJ783 0U 12 C13/12 C19 Switched and Monitored 48A/200-240V/3Ph PDU w/ IEC60309 460P9 line cord
46M4002 1U 9 C19/3 C13 Switched and Monitored DPI PDU (without line cord)
46M4003 1U 9 C19/3 C13 Switched and Monitored 60A 3 Phase PDU with IEC 309 3P+Gnd line cord
46M4004 1U 12 C13 Switched and Monitored DPI PDU (without line cord)
46M4005 1U 12 C13 Switched and Monitored 60A 3 Phase PDU with IEC 309 3P+Gnd line cord
Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets)
71762NX Ultra Density Enterprise C19/C13 PDU Module (without line cord)
71763NU Ultra Density Enterprise C19/C13 PDU 60A/208V/3ph with IEC 309 3P+Gnd line cord
C13 Enterprise PDUs (12x IEC 320 C13 outlets)
39M2816 DPI C13 Enterprise PDU+ (without line cord)
39Y8941 DPI Single Phase C13 Enterprise PDU (without line cord)
C19 Enterprise PDUs (6x IEC 320 C19 outlets)
39Y8948 DPI Single Phase C19 Enterprise PDU (without line cord)
39Y8923 DPI 60A 3 Phase C19 Enterprise PDU with IEC 309 3P+G (208 V) fixed line cord
Front-end PDUs (3x IEC 320 C19 outlets)
39Y8938 DPI 30amp/125V Front-end PDU with NEMA L5-30P line cord
39Y8939 DPI 30amp/250V Front-end PDU with NEMA L6-30P line cord
39Y8934 DPI 32amp/250V Front-end PDU with IEC 309 2P+Gnd line cord
39Y8940 DPI 60amp/250V Front-end PDU with IEC 309 2P+Gnd line cord
39Y8935 DPI 63amp/250V Front-end PDU with IEC 309 2P+Gnd line cord
NEMA PDUs (6x NEMA 5-15R outlets)
39Y8905 DPI 100-127V PDU with Fixed NEMA L5-15P line cord
Line cords for PDUs that ship without a line cord
40K9611 DPI 32a Line Cord (IEC 309 3P+N+G)
40K9612 DPI 32a Line Cord (IEC 309 P+N+G)
40K9613 DPI 63a Cord (IEC 309 P+N+G)
40K9614 DPI 30a Line Cord (NEMA L6-30P)
40K9615 DPI 60a Cord (IEC 309 2P+G)
40K9617 DPI Australian/NZ 3112 Line Cord
40K9618 DPI  Korean 8305 Line Cord

For more information, see the Lenovo Press documents in the PDU category:
https://lenovopress.com/servers/options/pdu

Rack cabinets

Rack installation kits are described in the Rack installation section.

The following table lists the supported rack cabinets.

Table 65. Rack cabinets
Part number Description
93072RX 25U Standard Rack
93072PX 25U Static S2 Standard Rack
93634PX 42U 1100mm Dynamic Rack
93634EX 42U 1100mm Dynamic Expansion Rack
93604PX 42U 1200mm Deep Dynamic Rack
93614PX 42U 1200mm Deep Static Rack
93084EX 42U Enterprise Expansion Rack
93084PX 42U Enterprise Rack
93074RX 42U Standard Rack
Withdrawn rack cabinets
201886X* 11U Office Enablement Kit
93604EX* 42U 1200mm Deep Dynamic Expansion Rack
93614EX* 42U 1200mm Deep Static Expansion Rack
93074XX* 42U Standard Rack Extension
93624PX* 47U 1200mm Deep Static Rack
93624EX* 47U 1200mm Deep Static Expansion Rack
93634BX* PureFlex System 42U Expansion Rack
93634DX* PureFlex System 42U Expansion Rack
93634AX* PureFlex System 42U Rack
93634CX* PureFlex System 42U Rack

* Withdrawn from marketing

For specifications about these racks, see the Lenovo Rack Cabinet Reference, available from:
https://lenovopress.com/lp0658-lenovo-rack-cabinet-reference

For more information, see the list of Product Guides in the Rack cabinets category:
https://lenovopress.com/servers/options/racks

KVM console options

The following table lists the supported KVM consoles, keyboards, and KVM switches.

Table 66. Console keyboards
Part number Description
Consoles
17238BX 1U 18.5" Standard Console (without keyboard)
Console keyboards
7ZB7A05469 ThinkSystem Keyboard w/ Int. Pointing Device USB - Arabic 253 RoHS v2
7ZB7A05468 ThinkSystem Keyboard w/ Int. Pointing Device USB - Belg/UK 120 RoHS v2
7ZB7A05206 ThinkSystem Keyboard w/ Int. Pointing Device USB - Czech 489 RoHS v2
7ZB7A05207 ThinkSystem Keyboard w/ Int. Pointing Device USB - Danish 159 RoHS v2
7ZB7A05208 ThinkSystem Keyboard w/ Int. Pointing Device USB - Dutch 143 RoHS v2
7ZB7A05210 ThinkSystem Keyboard w/ Int. Pointing Device USB - Fr/Canada 445 RoHS v2
7ZB7A05209 ThinkSystem Keyboard w/ Int. Pointing Device USB - French 189 RoHS v2
7ZB7A05211 ThinkSystem Keyboard w/ Int. Pointing Device USB - German 129 RoHS v2
7ZB7A05212 ThinkSystem Keyboard w/ Int. Pointing Device USB - Greek 219 RoHS v2
7ZB7A05213 ThinkSystem Keyboard w/ Int. Pointing Device USB - Hebrew 212 RoHS v2
7ZB7A05214 ThinkSystem Keyboard w/ Int. Pointing Device USB - Hungarian 208 RoHS v2
7ZB7A05215 ThinkSystem Keyboard w/ Int. Pointing Device USB - Italian 141 RoHS v2
7ZB7A05216 ThinkSystem Keyboard w/ Int. Pointing Device USB - Japanese 194 RoHS v2
7ZB7A05217 ThinkSystem Keyboard w/ Int. Pointing Device USB - Korean 413 RoHS v2
7ZB7A05218 ThinkSystem Keyboard w/ Int. Pointing Device USB - LA Span 171 RoHS v2
7ZB7A05219 ThinkSystem Keyboard w/ Int. Pointing Device USB - Norwegian 155 RoHS v2
7ZB7A05220 ThinkSystem Keyboard w/ Int. Pointing Device USB - Polish 214 RoHS v2
7ZB7A05221 ThinkSystem Keyboard w/ Int. Pointing Device USB - Portugese 163 RoHS v2
7ZB7A05222 ThinkSystem Keyboard w/ Int. Pointing Device USB - Russian 441 RoHS v2
7ZB7A05223 ThinkSystem Keyboard w/ Int. Pointing Device USB - Slovak 245 RoHS v2
7ZB7A05231 ThinkSystem Keyboard w/ Int. Pointing Device USB - Slovenian 234 RoHS v2
7ZB7A05224 ThinkSystem Keyboard w/ Int. Pointing Device USB - Spanish 172 RoHS v2
7ZB7A05225 ThinkSystem Keyboard w/ Int. Pointing Device USB - Swed/Finn 153 RoHS v2
7ZB7A05226 ThinkSystem Keyboard w/ Int. Pointing Device USB - Swiss F/G 150 RoHS v2
7ZB7A05227 ThinkSystem Keyboard w/ Int. Pointing Device USB - Thai 191 RoHS v2
7ZB7A05467 ThinkSystem Keyboard w/ Int. Pointing Device USB - Trad Chinese/US 467 RoHS v2
7ZB7A05228 ThinkSystem Keyboard w/ Int. Pointing Device USB - Turkish 179 RoHS v2
7ZB7A05229 ThinkSystem Keyboard w/ Int. Pointing Device USB - UK Eng 166 RoHS v2
7ZB7A05470 ThinkSystem Keyboard w/ Int. Pointing Device USB - US Eng 103P RoHS v2
7ZB7A05230 ThinkSystem Keyboard w/ Int. Pointing Device USB - US Euro 103P RoHS v2
Console switches
1754D2X Global 4x2x32 Console Manager (GCM32)
1754D1X Global 2x2x16 Console Manager (GCM16)
1754A2X Local 2x16 Console Manager (LCM16)
1754A1X Local 1x8 Console Manager (LCM8)
Console switch cables
43V6147 Single Cable USB Conversion Option (UCO)
39M2895 USB Conversion Option (4 Pack UCO)
46M5383 Virtual Media Conversion Option Gen2 (VCO2)
46M5382 Serial Conversion Option (SCO)

For more information, see the list of Product Guides in the KVM Switches and Consoles category:
http://lenovopress.com/servers/options/kvm

Lenovo Financial Services

Lenovo Financial Services reinforces Lenovo’s commitment to deliver pioneering products and services that are recognized for their quality, excellence, and trustworthiness. Lenovo Financial Services offers financing solutions and services that complement your technology solution anywhere in the world.

We are dedicated to delivering a positive finance experience for customers like you who want to maximize your purchase power by obtaining the technology you need today, protect against technology obsolescence, and preserve your capital for other uses.

We work with businesses, non-profit organizations, governments and educational institutions to finance their entire technology solution. We focus on making it easy to do business with us. Our highly experienced team of finance professionals operates in a work culture that emphasizes the importance of providing outstanding customer service. Our systems, processes and flexible policies support our goal of providing customers with a positive experience.

We finance your entire solution. Unlike others, we allow you to bundle everything you need from hardware and software to service contracts, installation costs, training fees, and sales tax. If you decide weeks or months later to add to your solution, we can consolidate everything into a single invoice.

Our Premier Client services provide large accounts with special handling services to ensure these complex transactions are serviced properly. As a premier client, you have a dedicated finance specialist who manages your account through its life, from first invoice through asset return or purchase. This specialist develops an in-depth understanding of your invoice and payment requirements. For you, this dedication provides a high-quality, easy, and positive financing experience.

For your region specific offers please ask your Lenovo sales representative or your technology provider about the use of Lenovo Financial Services. For more information, see the following Lenovo website:

http://www.lenovofs.com

Related product families

Product families related to this document are the following:

Products specifications
Hard Drive 3.5"
Processor Xeon-Silver