HPE ProLiant DL320 Gen11 2 GPU FIO Enablement Kit
|
P62197-B21
|
Notes:
- If Qty=1 Double Wide GPU is selected with GPU CTO Server, then 'GPU 4xDC NVMe FIO Kit' or '2 GPU FIO Enable Kit' must be selected.
- If Qty=2 Double Wide GPU is selected with GPU CTO Server, then ‘2 GPU FIO Enable Kit' must be selected
- Cannot be selected with any other GPU enablement kit.
- If '2 GPU FIO Enable Kit' is selected along with 4SFF Drive cage, then MR416i-p controller or Gen5 Retimer card and 4SFF TM Cable Kit must be selected.
- If Qty=1 Single Wide GPU is selected with GPU CTO Server, then 'GPU 4xDC NVMe FIO Kit' or '2 GPU FIO Enable Kit' or '4SW GPU FIO Enable Kit’ must be selected.
If Qty=2 Single Wide GPU is selected with GPU CTO server then ‘2 GPU FIO Enable Kit' or '4SW GPU FIO Enable Kit’ must be selected.
|
|
HPE ProLiant DL320 Gen11 Serial Port Enablement Kit
|
P58829-B21
|
Notes: Max = 1
|
|
HPE ProLiant DL320 Gen11 Primary GPU 8-pin Power Cable Kit
|
P62201-B21
|
HPE ProLiant DL320 Gen11 Secondary GPU 8-pin Power Cable Kit
|
P62203-B21
|
HPE ProLiant DL320 Gen11 Primary GPU 16-pin Power Cable Kit
|
P62205-B21
|
HPE ProLiant DL320 Gen11 Secondary GPU 16-pin Power Cable Kit
|
P62207-B21
|
Notes:
- P62205-B21 & P62207-B21 require selection of L40 GPU.
- If Qty=1 of L40 GPU is selected, then Primary GPU 16p Power Cable Kit (P62205-B21) must be selected.
- If Qty=2 of L40 GPU is selected, then Primary GPU 16p Power Cable Kit (P62205-B21) and Secondary GPU 8p Power Cable Kit (P62207-B21) must be selected.
- P62201-B21 & P62203-B21 require selection of A16 GPU.
- If Qty=1 of A16 GPU is selected, then Primary GPU 8p Power Cable Kit (P62201-B21) must be selected.
- If Qty=2 of A16 GPU is selected, then Primary GPU 8p Power Cable Kit (P62201-B21) and Secondary GPU 8p Power Cable Kit (P62203-B21) must be selected.
|
|
HPE ProLiant DL320 Gen11 Primary GPU 16-pin Advanced Power Cable Kit
|
P69104-B21
|
HPE ProLiant DL320 Gen11 Secondary GPU 16-pin Advanced Power Cable Kit
|
P69106-B21
|
Notes:
- If Qty=1 of L40s GPU is selected then Prim GPU 16p Adv Power Kit must be selected.
- If Qty=2 of L40s GPU is selected then Prim GPU 16p Adv Power Kit and Sec GPU 16p Advanced Power Kit must be selected.
- Requires selection of L40s GPU
|
|
HPE ProLiant DL320 Gen11 4SFF Tri-Mode Cable Kit
|
P62189-B21
|
Notes:
- Supported only with GPU CTO Server.
- If 4SFF U.3 drive cage is selected with MR416i-p controller, then 'HPE DL320 Gen11 4SFF TM Cable Kit.'
- Requires selection 4SFF U.3 Drive cage.
- Max=1 of 'GPU 4xDC NVMe FIO Kit' or '4SFF TM Cable Kit' can be selected.
|
|
HPE ProLiant DL320 Gen11 2x Type-p NVMe Cable Kit
|
P62183-B21
|
Notes:
- Supported only with GPU CTO Server.
- Requires selection of Gen5 Retimer card.
- Requires selection of 8EDSFF Drive cage.
- Max=1 of these kits is allowed for selection GPU 4xDC NVMe FIO Kit or 4SFF TM Cable Ki or Gen5 Retimer cable
- If 8EDSFF Drive cage is selected with Gen5 Retimer card then HPE DL320 Gen11 2xType-p NVMe Cable Kit must be selected and defaulted
|
|
HPE ProLiant DL320 Gen11 SR932i-p NVMe Cable Kit
|
P62185-B21
|
Notes:
- Supported only with GPU CTO Server.
- Requires selection of 8EDSFF Drive cage.
- Max=1 of these kits is allowed for selection GPU 4xDC NVMe FIO Kit or 4SFF TM Cable Ki or Gen5 Retimer cable
- If 8EDSFF drive cage is selected with SR932i-p controller, then 'SR932i-p NVMe Cable Kit' must be selected and defaulted.
- Requires selection of SR932i-p controller
|
|
|
RAID Settings
|
|
HPE RAID 0 Drive 1 FIO Setting
|
339777-B21
|
HPE RAID 1 Drive 1 FIO Setting
|
339778-B21
|
HPE RAID 5 Drive 1 FIO Setting
|
339779-B21
|
HPE Raid 5 w/SP Drive 1 FIO Setting
|
339780-B21
|
HPE RAID FIO Advanced Data Guarding Option
|
339781-B21
|
Notes:
- General RAID rules:
o Only a single set of RAID will be offered and will only be applied to all applicable drives installed in a server.
o RAID requires the selection of a Smart Array controller and a specific number of matching drives. (i.e., same part number).
o If RAID is selected, and only SAS or SATA, or NVMe drives are configured, then all drives must be the same part number. (i.e., matching drives).
o If RAID is selected and both SAS and SATA drives are configured, only the SAS drives will be used in the RAID set. (SAS drives must be the same part number; SATA drives can vary in part numbers).
o If RAID is selected and NVMe, SAS, and SATA drives are configured, then only the NVMe drives will be used in the RAID set. (NVMe drives must be the same part number; SAS & SATA drives can vary in part numbers).
o RAID must be selected if both Factory Installed OS and Smart Array controller (embedded or otherwise) are present.
o (vii) RAID 0 requires at least 1 drive.
o RAID 1 requires at least 2 or even number of drives.
o RAID 1 with Spare requires at least 3 drives.
o RAID 5 requires at least 3 drives.
o RAID 5 with Spare requires at least 4 drives.
o RAID 6 requires at least 4 drives.
- If SR932i-p/ MR416i-p/ MR416i-o/ MR408i-o is the Primary controller, then all RAID levels are allowed.
- If MR216i-o/MR216i-p/ Standard VROC is the primary controller, then only the following RAID levels are allowed: 0, 1.
- If Premium VROC is the primary controller, then the following RAID levels are allowed: 0, 1, 5.
- If Direct Attach is the Primary controller, then RAID is NOT allowed.
- If RAID is selected in a configuration with VROC and internal controller, then Customer Defined RAID Setting (389692-B21) must be selected.
- HPE Recommends using the below standard RAID Settings,
o 339777-B21 HPE RAID 0 Drive 1 FIO Setting
o 339778-B21 HPE RAID 1 Drive 1 FIO Setting
o 339779-B21 HPE RAID 5 Drive 1 FIO Setting
o 339780-B21 HPE RAID 5 w/SP Drive 1 FIO Setting
|
|
HPE Customer Defined RAID Setting Service
|
389692-B21
|
Notes:
- The following RAID rules do not apply:
o Max of 1 RAID level per server.
o All integrated hard drives must match.
o Minimum drive quantity requirement for each RAID level.
o RAID level must be selected if Factory Installed OS is present and Smart Array SAS controller (embedded or otherwise) is the primary controller.
- At least 1 hard drive must be on order.
- Preinstalled OS must be on order.
- A Customer Intent Document (CID) must be supplied if this part number is ordered.
- This Customer Intent Document should include all details about the desired RAID custom configuration (This includes Drive part numbers and quantities, RAID levels desired, which drives should be applied to each RAID level, and if a preinstalled OS has been ordered - which RAID set it should be installed on).
|
|
|
Embedded Management
|
|
HPE iLO Common Password FIO Setting
|
|
HPE iLO Common Password FIO Setting
|
P08040-B21
|
Notes:
- Replaces iLO default randomized password with an HPE-defined common password. HPE highly recommends changing this password immediately after the initial onboarding process.
- Customers who want to choose their own custom iLO default password should use the HPE Factory Express Integration Services.
|
|
HPE iLO Advanced
|
|
HPE iLO Advanced Electronic License with 1yr Support on iLO Licensed Features
|
E6U59ABE
|
HPE iLO Advanced 1-server License with 1yr Support on iLO Licensed Features
|
512485-B21
|
HPE iLO Advanced AKA Tracking License with 1yr Support on iLO Licensed Features
|
512487-B21
|
HPE iLO Advanced Electronic License with 3yr Support on iLO Licensed Features
|
E6U64ABE
|
HPE iLO Advanced 1-server License with 3yr Support on iLO Licensed Features
|
BD505A
|
HPE iLO Advanced AKA Tracking License with 3yr Support on iLO Licensed Features
|
BD507A
|
HPE Converged Infrastructure Management Software
|
|
HPE OneView including 3yr 24x7 Support Flexible Quantity E-LTU
|
E5Y35AAE
|
HPE OneView w/o iLO including 3yr 24x7 Support Flexible Quantity E-LTU
|
P8B26AAE
|
Notes: Licenses ship without media. The HPE OneView Media Kit can be ordered separately or downloaded.
|
|
|
HPE Security
|
|
HPE iLO Common Password FIO Setting
|
P08040-B21
|
Notes:
- Replaces iLO default randomized password with an HPE-defined common password. HPE highly recommends changing this password immediately after the initial onboarding process.
- Customers who want to choose their own custom iLO default password should use the HPE Factory Express Integration Services.
|
|
HPE Bezel Lock Kit
|
875519-B21
|
Notes: Requires the bezel kit (P50450-B21).
|
|
HPE ProLiant Gen11 1U Common Bezel Kit
|
P50450-B21
|
HPE ProLiant DL320 Gen11 Intrusion Detection Cable Kit
|
P55417-B21
|
|
Optional Upgrades
|
|
HPE 96W Smart Storage Lithium-ion Battery with 145mm Cable Kit
|
P01366-B21
|
HPE Smart Storage Hybrid Capacitor with 145mm Cable Kit
|
P02377-B21
|
Notes: Provides backup power for multiple HPE storage controllers or other devices.
|
|
|
HPE Tape Backup
For the complete range of tape drives, autoloaders, libraries, and media, see:
https://www.hpe.com/us/en/storage/storeever-tape-storage.html For hardware and software compatibility of Hewlett Packard Enterprise tape backup products http://www.hpe.com/storage/BURAcompatibility
|
|
HPE Racks
· Please see the HPE Advanced Series Racks QuickSpecs for information on additional racks options and rack specifications. HPE G2 Advanced Series Racks
· Please see the HPE Enterprise Series Racks QuickSpecs for information on additional racks options and rack specifications. HPE G2 Enterprise Series Racks
|
|
HPE Power Distribution Units (PDUs)
· Please see the HPE Basic Power Distribution Units (PDU) QuickSpecs for information on these products and their specifications.
· Please see the HPE Metered Power Distribution Units (PDU) QuickSpecs for information on these products and their specifications. Please see the HPE Intelligent Power Distribution Unit (PDU) QuickSpecs for information on these products and their specifications.
· Please see the HPE Metered and Switched Power Distribution Units (PDU) QuickSpecs for information on these products and their specifications.
|
|
Uninterruptible Power Systems (UPS)
· To learn more, please visit the HPE Uninterruptible Power Systems (UPS) web page.
· Please see the HPE Direct Flow Three Phase Uninterruptible Power System QuickSpecs for information on these products and their specifications.
· Please see the HPE Line Interactive Single-Phase UPS QuickSpecs for information on these products and their specifications.
|
|
HPE Rack Options
Please see the HPE KVM Switches web page for information on these products and their specifications.
|
|
Easy Install Rail Kits
Easy Install rail kits contain telescoping rails, which allow for in-rack serviceability.
To assist in installing the server into the rack, an optional installation tool is available by contacting your local services representative.
Notes:
- Hewlett Packard Enterprise recommends that a minimum of two people are required for all Rack Server installations. Please refer to your installation instructions for proper tools and the number of people to use for any installation.
- HPE rail kits are designed to work with HPE racks in compliance with industry standard EIA-310-E. In the event a customer elects to purchase a third-party rack for use with an HPE rail kit, any such use is at customer’s own risk. HPE makes no express or implied warranties with respect to such third-party racks and specifically disclaims any implied warranties of merchantability and fitness for a particular purpose. Furthermore, HPE has no obligation and assumes no liability for the materials, design, specifications, installation, safety, and compatibility of any such third-party racks with any rail kits, including HPE rail kits.
|
HPE ProLiant DL300 Gen10 Plus 1U Cable Management Arm for Rail Kit
|
P26489-B21
|
Notes:
- Not supported with 12LFF CTO Server
- DL300 Gen10+ 1U CMA for Rail Kit' requires the selection of 'EI Rail Kit 1' or 'Easy Install Rail 2 Kit'.
|
|
HPE Easy Install Rail 1 Kit
|
P52349-B21
|
Notes:
- Supported only with 8SFF CTO Server.
- DL300 Gen10+ 1U CMA for Rail Kit' requires the selection of 'EI Rail Kit 1' or 'Easy Install Rail 2 Kit'.
|
|
HPE DL3XX Gen11 Easy Install Rail 2 Kit
|
P52351-B21
|
Notes:
- Supported only with 4LFF CTO Server.
- DL300 Gen10+ 1U CMA for Rail Kit' requires the selection of 'EI Rail Kit 1' or 'Easy Install Rail 2 Kit'.
|
|
HPE Easy Install Rail 9 Kit
|
P52353-B21
|
Notes:
- Supported only with 12LFF CTO Server.
- DL325 Gen10+ CMA requires the selection of EI Rail Kit 9.
|
|
|
HPE USB and SD Options
|
|
Notes: In vSphere 7.0, VMware made changes that impact the use of an SD Card/USB media as a standalone boot device and will be removing support for them after version 7.x.
SD Card/USB media can still be used as a standalone boot option through all 7.x releases via published Customer Advisory Usage of SD Card/USB Devices As Standalone Boot Devices Has Changed Due to System Storage Changes For VMware ESXi 7.0 (Or Later).
For any major release beyond VMware ESXi 7.x, VMware will require M.2 or another local persistent device as the standalone boot option.
|
|
HPE Support Service
Installation & Startup Services
|
HPE ProLiant DL/ML Install Service
|
U4554E
|
HPE ProLiant DL/ML Startup Service
|
U4555E
|
Tech Care
|
HPE 3 Year Tech Care Essential DL320 Gen11 HW Service
|
H93M2E
|
HPE 3 Year Tech Care Essential wDMR DL320 Gen11 HW Service
|
H93M3E
|
HPE 5 Year Tech Care Essential DL320 Gen11 HW Service
|
H93P6E
|
HPE 5 Year Tech Care Essential wDMR DL320 Gen11 HW Service
|
H93P7E
|
|